8.

BATTERY CHARGING - AC CONNECTIONS

8.1
This battery charger is for use on a circuit having a nominal rating more
than 120 volts (or "This appliance is rated more than 15 amperes and is
for use on a circuit having a nominal rating of 120 volts") and is factory-
equipped with a specific electric cord and plug to permit connection to an
acceptable electric circuit. Make sure that the charger is connected to an
outlet having the same configuration as the plug. No adapter should be
used with this charger.
8.2
AC input rating,
amperes
At least
0
2
3
4
5
6
8
10
12
14
16
18
a
If the input rating of a charger is given in watts rather than in
amperes, the corresponding ampere rating is to be determined
by dividing the wattage rating by the voltage rating
example:
9.
ASSEMBLY INSTRUCTIONS
9.1
Using the quick Connector Clamps
Plug the clamp's connector into the connector attached to the 1562A.
Follow charging instructions as outlined in section 10.
9.2
Using the quick Connector Ring Terminals
Ring terminals can be permanently mounted to battery. If permanently
mounted, make sure the ring terminal cables are not obstructing or touch-
ing any live components in the vehicle. ALWAYS ensure ring terminals
are properly mounted prior to charging.
Turn the vehicle's ignition OFF before making ring terminal connections.
Attach the red ring terminal (+) to the positive terminal of the battery.
a
But less
25
than
(7.6)
2
18
3
18
4
18
5
18
6
18
8
18
10
18
12
16
14
16
16
16
18
14
20
14
1250 watts/125 volts = 10 amperes
AWG size of cord
Length of cord, feet (m)
50
(15.2)
18
18
18
18
16
16
14
14
12
12
12
12
5
100
150
(30.5)
(45.6)
18
16
16
14
16
14
14
12
14
12
12
10
12
10
10
8
10
8
10
8
8
8
8
6