WIRING DIAGRAM

POWER SUPPLY
RELAY 1
RELAY 2
EXIT BUTTON
DOOR CONTACT
PROGRAMMATION
Enter programming mode
Exit programming mode
Note: Exit programming mode is automatic after 60 seconds idle.
Enter programming mode
Select the menu by pressing
Enter "X" the digits number (from 2 to 6).
Defaults Master Codes:
X=2 –> "12"; X=3 –> "123"; X=4 –> "1234"; X=5 –> "12345"; X=6 –> "123456"
Exit the programming mode
KEY:
O
6-1622780 - rev.4 - 02/08/2021
Black / -
Red / +
Rose / COM1
White / NO1
Rose / COM1
Clear Blue / NC1
Purple / COM2
Blue / NO2
Purple / COM2
Grey / NC2
Orange / BP1
Green / GND
Yellow / BP2
Green / GND
Brown / BP1
Green / GND
Enter the MASTER CODE twice.
(default MASTER CODE = "1234")
Press
once.
Change code digits number
Attention: This operation delete every registered codes.
.
.
G
= LED Orange;
= LED Green;
= Small sound;
Ground
+Vcc
Common Relay 1
Contact Normally Open Relay 1
Common Relay 1
Contact Normally Close Relay 1
Common Relay 2
Contact Normally Open Relay 2
Common Relay 2
Contact Normally Close Relay 2
Button relay 1
Ground
Button relay 2
Ground
Button relay 1
Ground
R
= LED Red;
= Long sound
} VCC
} NO1
} NC1
} NO2
} NC2
} BP1
} BP2
} CP
= LED flashing