Electrical Connection En - Abicor Binzel TCS Compact Manual De Instrucciones

Ocultar thumbs Ver también para TCS Compact:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TCS Compact
6.2 Electrical connection
The torch cleaning station is connected to the power supply via an integrated plug-in connection. The necessary control
signals are also transmitted via this plug.
Fig. 11
Electrical connection
NOTICE
• Ready-to-use control leads are available in lengths of 5m and 10m (optional).
• If the device uses a transistor output, the following applies to the electrical connection:
High-side switch (PNP/sourcing) or transistor output: Low-side switch (NPN/sinking)
 13.1 Circuit diagram on page EN-36
BAL.0617.0 • 2021-05-20
6 Putting into operation
Operating
1/A PE
voltage
2/B GND (0 V)
3/C 24 V DC/200 mA
Input
4/D 24 V DC/2,8 W
Loosen the clamping cylinder/
Close wire cutter (Y3)
5/E 24 V DC/2,8 W
Lift up(Y1)
6/F 24V/2,8 W
Motor Rotation (Y2)
Output
7/G 24 V DC/max. 100 mA
Lift cylinder is down(S1)
8/H 24 V/max. 100 mA
Clamping cylinder is open (S2)
EN - 19