Care and Cleaning
 Prior to a long period of non-use
1.
Operate the FAN ONLY mode for several hours to dry out the
inside.
• Press
.
2.
After operation stops, turn off the circuit breaker for the room
air conditioner.
3.
Take out the batteries from the remote controller.
 We recommend periodical maintenance
• In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor
performance. It is recommended to have periodical maintenance by a qualifi ed contractor in addition to regular cleaning by
the user.
• For qualifi ed contractor maintenance, please contact the dealer where you bought the air conditioner.
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
ATXP20/25/35K2V1B
ATXP20/25/35K3V1B
Refrigerant type:
R32
(1)
GWP
value:
675
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation.
Please contact your local dealer for more information.
NOTICE regarding tCO
2
In Europe, the greenhouse gas emissions of the total refrigerant charge in the system (expressed as tonnes CO
is used to determine the maintenance intervals. Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in kg] / 1000
ATX20/25/35K2V1B
Refrigerant type:
R410A
2087.5
GWP
(1)
value:
eq
Care
-equivalent)
2
22
22