20
UK
- Embed the operator box in the foundation hole.
FITTING THE GATE
N.B. Check that the cement in the foundation hole has dried sufficiently before installing the operator.
1- Fit the lever unit to the box pin (10) AJ00720 - AJ00730 (14).
2- Procure a U-bracket of the dimensions indicated in (11) and close it on the pillar side using a plate as shown in
(12/a) and (12/b).
3- Weld the U-bracket or the gate on the operator support arm (13).
4- Position the gate in the guide bracket and hinge it in the upper part.
5- Check manually that the gate is free to open and close coming to a complete halt on the mechanical end-stops.
The leaf must move smoothly and uniformly without irregular friction.
OPERATOR INSTALLATION
1- Open and close the gate leaf determining the desired opening and closing by means of the mechanical limit
switches A(14a).
2- Once the limit switches have been adjusted, move the leaf into the gate-open position.
3- Fasten the operator checking that it is exactly positioned (14a - 14b).
4- If using the limit switches, refer to the next paragraph.
5- Fit the connecting rod (left or right) as shown (15).
6- At this stage, it is advisable to grease the operator output shaft and the lever fastening pins.
7- Power the operator and move the leaf into the gate-closed position.
8- Proceed with installation of the second operator (where applicable) repeating the above described procedures.
9- Fit the cover on the operator using the screws provided (16).
LIMIT SWITCH UNIT (17-18)
The kit is made up of:
a) Limit switch disc
b) Limit switch
c) Sensor board cable 4x0.5 mm²: blue= close, purple= open, red= positive, brown= negative
d) Magnets
e) Adjustment screws
f ) Retaining screws
LIMIT SWITCH FITTING AND ADJUSTMENT
1- Fit the two cheese-headed screws e(18) directly on the operator body.
2- Fasten the sensor board c(18) using the two screws f(18) above the two screws e(18), and run the output cable
through the grooves on the operator.
3- Secure the limit switch disc on the output lever using the screws M3 x 6 mm (20).
4- Fasten the assembly formed by the disc and the lever on the operator output shaft using the pin (20).
5- Fasten the connecting rod between the output levers using the relative pins and seeger (15).
6- POWER THE OPERATOR
7- Taking the sensor as reference, assemble the two limit switches b(19) on the disc a(19) using the screws and nuts
c(19) and fasten one in the gate-open position and the other one in the gate-closed position and run a full cycle.
GROUND