Table 4: Operating malfunctions
Problem
The skewer does not turn
GAS CONNECTION
All the gas connection, transformation and pressure control operations must be per-
formed by authorised personnel who must have specific technical skills and special
abilities in the specific sector. This also applies for all extraordinary maintenance oper-
ations such as lubrication and/or faucet replacement and thermocouple or burner
replacement.
Equip the appliance gas supply tube with a faucet to be able to cut of gas supply in the
event of need.
The faucet (not supplied with the appliance) must be installed in a visible and accessi-
ble position in order to easily identify its operating status (open or closed).
GAS SUPPLY TRANSFORMATION
The appliance is marketed with indications of the gas mains used by the manufacturer
for inspections.
If the gas mains do not correspond to the one used for inspection, before connecting
the gas mains, the installation technician must "transform" the appliance and indicate
the type of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no
gas leaks or operating defects, test the appliance and indicate the type of gas in use
on the identification plate.
To "transform" and adapt the appliance to the gas mains in use, close the gas supply
faucet and perform the listed operations.
– burner nozzle replacement
– Heat power adjustment to minimum
Translation of the original instructions
Causes
Main switch off.
No mains power.
Food product to be cooked too
heavy
- 19 -
GYROS (GAS POWERED)
Solutions
Turn on main switch.
Contact your dealer or
authorised service centre.
Reduce the weight of the food
product to be cooked
English language
GB