Cleaning Process - 3M Accuspray HGP Manual De Proprietário

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
ATTENTION
Note: Do Not Put In Gun Washer.
Solvent left in the spray gun air passages could
result in a poor quality coating finish. Do not use
any cleaning method which may allow solvent into
the spray gun air passages. Do not expose air flow
control valve and gauges to solvent as damage
may occur.

Cleaning Process

1. Relieve the air and fluid pressure from the
spray gun and cup before servicing.
a. Turn off air supply to spray gun
b. Disconnect air line from spray gun
c. Turn gun upside down
d. Pull trigger to return coating to PPS cup
2. To retain unused coating or temporarily store
mixed material, see your Local, State, Federal
and OSHA guidelines, along with coating
manufacturer's recommendations for storage.
3. To flush spray gun, run water or compatible
and compliant solvent into the spray gun fluid
passage while triggering the spray gun until
the cleaning fluid appears clear.
Note: If feasible, clean atomizing head prior to disposal.
Dispose of all used atomizing heads in accordance
with federal, state and local regulations. To change
the atomizing head, refer to the section "Attaching the
Atomizing Head" on page 8.
11 11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

16587

Tabla de contenido