1.0
General
1.1
The controller user's manual is suitable for 0.3kW-0.6kW off-grid wind turbine generator and PV hybrid system.
1.2
Futures.
1.2.1
Automatic dump load while the wind turbine generator overload.
1.2.2
Batteries overcharge or over discharge protection.
1.2.3
Protect cable connect to batteries inverse.
1.2.4
Protect batteries charge to solar panel (at night).
1.2.5
Protect electric shock.
2.0
Input Power of Wind Energy:
Input Voltage of Wind Energy:
Peak Power of Solar Board:
Peak Voltage of Solar Board:
Output Voltage of Controller:
Over Voltage of Protection of Wind Energy's Output:
Over Electricity of Protection of Wind Energy's Output:
Storage Battery:
Max Output Electricity of Load End:
Trigger Voltage Protection:
Recovery Voltage Protection:
Voltage Protection of Full:
Work Environment:
Applicability:
3.0
Installing steps
3.1
Panels:
3.2
Installing steps.
3.2.1
Controller based on its protection level, housed in indoor and outdoor drying, ventilation, the controller may not be around the inflammable and explosive materials.
3.2.2
Controller should be mounted vertically, hanging solid.
3.2.3
Unloading an external device, due to unloading, the equipment surface temperature will exceed 85°C, must be firmly placed on the location where not to be
touched easily, meanwhile to maintain a well-ventilated, non-flammable, explosive goods.
3.2.4
Before wiring, to put the first wind turbine brakes manually switch to the "I"position, when wiring to prevent electric shock accidents caused by running generators.
3.2.5
Terminals in accordance with the upper part of the label, the right equipment connected to cable, cable cross-section required referring to the following table:
W1, W2, W3: Input terminals of wind turbine generator (Regardless of sequence);
S+: Solar panel +
S-: Solar panel -
B+: Batteries +
B-:Batteries -
COM: +DC12V
:-DC12V
3.2.6
Check the wiring correct, to put the wind turbine brakes manually switch to the "O" position, equipment into operation.
3.3
Running state, indicator function setting.
3.3.1
Running indicators.
Technical Specifications
400W
3- phase AC≤50V, P≤400W
350W
DC35V, I≤15A
DC14.4V
AC50±5V
DC22A±1A
Single or combination of various rated voltages12V, capability 50~250AH
Two way output load, each I<15A
DC10.5±0.3V
DC11.5±0.3V
DC14.4±0.2V
-20°C~ 50°C, RH 0~90%
Suit for adopting 12V Wind Solar complement system