Instructions for the window maker
Read the instructions carefully before starting to install
the product.
Follow all the instructions as incorrect installation can
lead to serious injury. Incorrect installation may be a source of
hazards. Installation must be carried out by professionally
competent staff. Installation, electrical connections and
adjustments must be carried out in accordance with Good
Practice and in compliance with the relevant regulations. The
drive system constructor is not responsible for failure to
comply with Good Practice when constructing the casements
for operation, or for any deformations which may occur during
use. The drive system constructor declines all responsibility
in the event of installation of components incompatible with
safety and trouble-free operation.
The window maker must check that the temperature range
marked on the operator is suited for the place of installation.
The partly completed machine is not suitable for installation in
locations with ionizing radiation; the installation and operating
environment must not generate risks for the operator. The
installation location must be well lit, assuming that the
ambient lighting in the partly completed machine's place of
use is of normal intensity. Do not install the product in
locations with explosive atmosphere: flammable gases or
fumes constitute a serious safety hazard. Inspect the product
for damage before starting installation. Check that the
existing structure has the necessary strength and stability.
Before starting to install the drive system, make all structural
modifications necessary for compliance with the safety
precautions and to protect or enclose all zones with crushing,
shearing or entrainment hazards, or hazards in general.
Before installing the actuator, check that the sash (bottom or
top hung) is in good mechanical condition, correctly balanced
and opens and closes properly.
Make sure that during the opening and closing movement
there are no collisions between the sash and frame and that
the sash does not hook onto the frame. The sash must have
Tab. A

Technical Data

THRUST FORCE
DRIVE FORCE
ADJUSTABLE CHAIN STROKES*
OPERATING SPEED
FRONT ADJUSTMENT
PARALLEL CONNECTION
POWER SUPPLY VARIA
230V 230VAC single-phase - 50 Hz
POWER SUPPLY VARIA 24V
CONSUMPTION
170 W (if 230VAC) - 40W (if 24 VDC)
CURRENT ABSORPTION VARIA 230V
CURRENT ABSORPTION VARIA 24V
THERMAL PROTECTION
CAPACITOR (S2)
BUILT-IN RELAY
WARNING LIGHT
REMOVABLE TERMINAL BOARD
PROTECTION RATING
USE NON HEAVY DUTY
OPERATING CYCLE
OPERATING TEMP
CHAIN STROKE
I0535003/10-2020
ISTRUZIONI - INSTRUCTIONS - INSTRUCTIONS - ANLEITUNG - INSTRUCCIONES - ИНСТРУКЦИЯ
150N
300N
from 90 to 400 mm
40mm/sec.
Max 10 mm
YES
24 VDC
0,8A in AC
1,8A in DC
medium with a load of 150N
140°C (only for VARIA230V)
3 μF (only for VARIA230V)
YES (only for VARIA230V)
YES
YES
IP 20
(VARIA230V only)
max 7 cycles in 5 min.
-20°C +40°C
300 mm
free movement.
After installation, make sure that the mechanism is properly
regulated and that the system protection and each manual
release work properly.
Before connecting the electricity supply, check that the
nameplate data are the same as those of the electricity supply
system.
Install a switch/omnipolar circuit breaker with contact opening
gap at least 3 mm (not supplied) on the electricity supply line.
Check that the upstream electricity supply system includes a
suitable RCD and overcurrent protection.
Packaging materials (plastic, polystyrene, etc.) must be
disposed of properly and must not be left within reach of
children as they constitute potential hazards. Genuine parts
must always be used when repairing or replacing products.
If the partly completed machine is installed in a position not
easily accessible to the operator, the structures needed to
access the working zone must be provided by the user in
accordance with the relevant safety regulations.
Safety Recommendations and Rules:
- N.B. The system is tested to withstand a maximum wind of
40 km per hour with the sash open. It should therefore be
connected to a wind-rain guard control unit (Pv1) and an
anemometer should be used.
- GIESSE products should be installed by industry specialists
who provide guarantees of the necessary technical
competence.
- Proceed in accordance with the constructor's instructions.
- The window maker must ensure that the device is installed
and operates correctly.
- Use of the product for purposes other than the intended
purpose or misuse is forbidden.
- Use genuine spare parts.
- Hazardous parts of the actuator must be installed at least 2.5
m above floor level.
Tab.B
A (mm)
C (mm)
0
90 (min)
13
103
25
115
38
128
51
141
64
154
76
166
89
179
102
192
115
205
127
217
140
230
No fitting
*
All the specifications have been written and verified with our best
attention. We do not undertake responsability for possible errors or
omissions. We reserve the right to introduce changes relative to
technological progress. Guarantee: The guarantee conditions can be
checked in the price list on the basis of the commercial agreements.
- 4/26 -
A (mm)
C (mm)
153
243
166
256
178
268
191
281
204
294
217
307
229
319
242
332
255
345
268
358
280
370
293
380