4. Clean the vacuum cleaner
• Clean the housing of the vacuum cleaner with a soft
and humid rag and let dry.
TROUBLESHOOTING
1. If your vacuum cleaner does
not start
• The appliance is not plugged-in, check that the
appliance is correctly plugged in.
2. If there is no suction
• n accessory or the tube is clogged. Unclog the
accessory tube or flexible hose.
• The lid was not closed properly: check that the
bag is properly installed and close the lid again.
3. If the suction of your vacuum
cleaner has dropped, it makes a
noise and whistles
• n accessory or the flexible hose is partially
clogged. Unclog the accessory tube or flexible
hose.
• The bag is full or saturated with fine dust. Put a
new bag in or empty the fabric dust bag.
• The foam-filter is saturated. Clean the foam-filter.
• If the bag fill indicator is red, the filtration system
is saturated.
- The Hepa* cassette: change the Hepa* cassette
and put it back in its housing.
- Washable HEP * filter cassette: clean or change
the washable HEP filter cassette and put it back
in its housing.
- The microfilter cassette*: withdraw the microfilter
from the cassette, and change it. Wash the grey
foam filter, squeeze it out and leave it to dry for at
W RR NTY
• This product has been designed for
domestic use only. ny professional use,
innapropriate use or failure to comply with
the instructions, the manufacturer accepts
no responsibility and the guarantee will not
apply.
• Clean the cover with a dry rag - fig. 29.
• Do not use abrasive or aggressive products.
least 12 hours. Then re-fit the cassette in its
housing.
• The electronic variable suction power selector is
in the minimum position.
Increase the power with the help of the electronic
variable suction power selector (except if you are
vacuuming delicate fabrics).
• If the mechanical power regulator on the power
nozzle is open, close the mechanical power
regulator.
4. If the bag fill indicator remains red
• The bag is full: replace the bag or clean the bag*.
5. If the floor head is hard to
move around
• Open the suction regulator on the handle or
reduce power.
6. If the power cable does not
rewind completely
• The power cable is slow in reentering its housing.
Pull the cable back out and press on the
automatic cable rewind pedal.
If you have any product problems or queries,
please contact our customer Relations Team first
for expert help and advice (see the contact details
on the last page).
• Read the instructions for use carefully
before using your appliance for the first
time: any use which does not conform to
these instructions will absolve Rowenta
from any liability.
17
EN