Table of Contents
Installation rules ................................................................ 3
Regulatory compliance .................................................... 3
Description ........................................................................ 3
Technical characteristics ................................................... 3
Front and rear view............................................................ 12
Wiring diagrams ................................................................ 15
Installation procedure ....................................................... 16
Configurations .................................................................. 24
Advanced configuration (via PC) ...................................... 28
Indicators .......................................................................... 29

INSTALLATION RULES.

Installation should be carried out observing current installation reg-
ulations for electrical systems in the Country where the products
are installed.
CONFORMITY.
EMC directive
Standards EN 60065, EN 61000-6-1, EN 61000-6-3 and EN
60118-4.
INFORMATION
FOR
2012/19/UE (WEEE)
In order to avoid damage to the environment and human
health as well as any administrative sanctions, any appli-
ance marked with this symbol must be disposed of separately
from municipal waste, that is it must be reconsigned to the dealer
upon purchase of a new one. Appliances marked with the crossed
out wheelie bin symbol must be collected in accordance with the
instructions issued by the local authorities responsible for waste
disposal.

Description

Audio electronic module (41001), audio video (41003) and audio
video teleloop wide-angle (41004) for Pixel Series modular panels,
can be used in systems with Due Fili Plus technology.
Can be installed with all the auxiliary modules of the 41000 series.
The audio-video version module (41003, 41004) is equipped with:
- camera and white LEDs lighting the shooting area with automat-
ic brightness control according to the ambient light.
- camera with zoom&scan mode, can be controlled directly from
the indoor unit (41004);
- two picture control modes, standard and enhanced portrait
(41004);
All the modules are moreover equipped with:
- automatic gain control on the power supplied by the loudspeak-
er, depending on the type of installation;
- echo suppressor, to remove the Larsen effect;
- automatic configuration of indoor unit addresses;
EN
USERS
UNDER
DIRECTIVE
- automatic configuration of speech unit addresses;
- light sensor function for automatically adjusting the brightness
according to the ambient light.
- four conventional indoor unit call buttons in two rows (2+2).
- can manage up to 84 button calls, using the additional button
modules 41010.
- control of an electric lock connected directly to terminals S+ and
S- and connection of a local additional button for lock opening at
terminals CA+ and CA- (terminals CA+ and CA- can alternative-
ly be configured via SaveProg software as the input of a sensor
for signalling "Door Open".
- front MiniUSB connector for connecting a PC via a USB-Min-
iUSB cable, for configuration using the Due Fili Plus system
management software "Save Prog", which can be downloaded
from the website www.vimar.com.
- Standard configurations can be made by using the four front call
buttons and their four indicator LEDs.
- Front LEDs to signal: call in progress/communication active;
lock command activation; no communication, panels in paral-
lel or directly involved in the call (building complex) and one of
these is already engaged in a conversation.
- input for optional local additional power supply unit (with power
supply unit 6923)
*
Impaired hearing function for people wearing a hearing aid
(41001, 41004 only).

Technical specifications

- Power supply from Due Fili Bus, via terminals B1 and B2: 28VDC
nominal.
- Minimum voltage on terminals B1 and B2: 21VDC
- Local power via terminals E+, E- if the electronic unit needs to
be powered via an additional power supply unit. The additional
power supply unit should be installed if the system's maximum
consumption exceeds the power supply unit's capacity.
- Absorption from Bus or from additional power supply unit:
Situation
on Stand-by
in communication
lock activation
maximum additional
modules
maximum
The maximum current delivered to the additional electronic
modules (back panel) is 500mA (maximum 8 additional mod-
ules).
Refer to the additional modules for sizing the load on the back
panel and on the bus.
- Operating temperature: -25 °C / +55°C.
- Video output signal 16 dBm (only for 41003, 41004)
- Protection class: IP54
- IK08-rated for protection against impact (Pixel)
41001
41003
41004
30 mA
30 mA
30 mA
180 mA
210 mA
260 mA
+ 50 mA
+ 50 mA
+ 50 mA
+ 130 mA + 130 mA + 130 mA
360 mA
390 mA
440 mA