Important! The fitting must be installed, flushed and
tested after the valid norms!
Assembly
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer in
position on the sink.
3.
Slide the fixation piece including the washer
over the threaded pins and tighten the nuts.
4.
Connect the supply pipes to the isolation
valves; cold right - hot left.
5.
Connect the pull rod to the pop-up waste.
The hot and cold supplies must be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Technical Data
Rate of flow:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Test certificate
DVGW
31701000
31703000
31716000
31721000
31726000
7,2 l/min 0,3 MPa
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
P-IX
SVGW
P-IX
X
18081/IA
P-IX
18081/IA
P-IX
18081/IA
P-IX
18081/IA
P-IX
18081/IA
English
Hansgrohe single lever mixers can be used together
with
hydraulically
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
If the continuous water heater causes any problems
or there is not enough flow of water, the
waterdimmer® (5a) located behind the aerator must
be removed.
To adjust the hot water limiter on single lever
mixers, please see page _1b.
No adjustment is necessary when using a
continuous flow water heater.
Spare parts (see page 3)
1
poignée
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
aerator
6
pull rod
7
fixing set
8
connection hose 3/8"
9
connection hose
10
seal
11
chain for plug
12
adapter for cartridge
13
screw
ACS
X
X
and
thermically
NF
WRAS
X
X
X
X
X
controlled
31793000
96338000
97406000
97209000
92730000
13912000
96657000
96016000
97206000
96321000
97608000
97109000
98750000
97736000
KIWA
X