Troubleshooting: LED Functionality
LED Behavior
All Keypad Types
"Reverse Waterfall"
LEDs light beginning at the bottom, continuing to light
until all are on; then LEDs go off beginning at the bottom,
continuing until all are off . Cycle then repeats .
No LED feedback at all, even when a button is pushed .
All LEDs are flashing rapidly .
Shade Keypads
Top and bottom LEDs are flashing together .
All LEDs flash 3 times, pause, then repeat .
Top and bottom LEDs light in an alternating pattern (top LED
lights, then goes off, then bottom LED lights, then goes off;
cycle repeats) .
Top and bottom LEDs blink slowly, and one other LED blinks
rapidly .
Other Keypads
A single LED is flashing .
"Forward Waterfall"
LEDs light and go off in sequence from top to bottom .
Installation Instructions
Meaning and Remedy
Unable to communicate on QS link, or alone on QS link . Check link
wiring .
No power to wallstation . Check power wiring .
Another device on QS link is in programming or assignment mode .
Take that device out of programming mode, or put this keypad into
programming mode and then exit programming mode, which turns
off programming mode on all devices .
Wallstation is in advanced programming mode . Press and hold the
top and bottom buttons for 3 seconds to exit advanced programming
mode .
Keypad is in assignment mode . Press and hold the top and bottom
buttons for 3 seconds to exit assignment mode .
Keypad is in assignment or limit set mode and cannot find or
communicate with any shades assigned to the QS link . Check the
shade wiring .
Wait 60 seconds, and the keypad will automatically return to normal
mode (without any user intervention) . Or, press and hold the top and
bottom buttons for 3 seconds to immediately exit the mode .
Keypad is in limit set mode, or another device on the link is in limit
set mode . Press and hold the top and raise buttons for 3 seconds to
exit limit set mode .
Keypad is in preset adjust mode . Press and hold the top and bottom
buttons to exit preset adjust mode .
Keypad is configured for either zone toggle, partitioning, or shade
toggle and is in programming mode . Press and hold the top and
bottom buttons to exit programming mode .
Keypad is configured for scene, panic, sequence, fine tune, or
scene/zone lockout, and is in programming mode . Press and hold
the top and bottom buttons to exit programming mode .
8
Occupant Copy