Installation
Only use the unit in its horizontal position and ensure stable seating on a firm ground downstream of the filter unit,
seen in flow direction. Fastening of the unit to the ground can be facilitated by removing the unit foot towards the rear
by unlocking the engagement lever on the underside of the unit foot (C). For installation, slide the unit body on the unit
foot until it engages.
The unit can be installed submersed (A = filter module) or dry (B = pump chamber). Always position the unit below the
water line to prevent dry running and the intake of air when switching on and operating the unit. Never connect the unit
to a water line. Use the enclosed adapter set to ease tube (6) or hose (7) installation. When fitting the tube, ensure
that the unit is installed without any tension.
Submerged installation (A)
At the pressure socket (2), connect the line returning the water into the pond. When submerged, insert the unit into the
filter module. Ensure that the unit never runs without water flowing through! Maximum installation depth: 4 metres.
Dry installation (B)
Disconnect the power supply first, then secure the unit to prevent unintentional switching on. Remove the contact protec-
tion (3) by turning it counter-clockwise. Do not reach into the pump opening (1). If necessary, fasten the suction hose using
the adapter set provided for tube (6) or hose (7) installation. Connect the suction hose to the suction socket (1).
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Start-up
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Cleaning the unit
Note!
Recommendation on regular cleaning:
 Clean the pump as required but at least twice a year.
 Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
 After cleaning, thoroughly rinse all parts in clean water.