Connection
Power supply/operation terminals
N L
A B
~
230V
1000W
C10
N L
N L
N
F5A / 250V
Power supply
busbars, Cat.
No. 049 26
Commissioning
– A la première mise sous tension de l'installation ou The
product is initialised when the installation is first switched
on or after a power break ≥ 200 ms
– On first use, the remote dimmer behaves as follows :
- short press = > maximum lighting level
- long press = > maximum lighting level then decreasing
level of lighting
– For subsequent use, see the description of operation
opposite.
Recommendation
To achieve the same level of dimming at each lighting point, use identical loads
S
V
D E
VE
Incandescent
230 VAC bulb
Tungsten halogen
230 VAC bulb
Tungsten halogen
bulb with ferroma-
gnetic transformer
17
18
Control terminals
A
B
A
B
A B
N L
/ 25 0V
F5 A
Operation
– The lighting level produced by pressing the key on the
peripheral device or the control pushbutton is as
follows :
- short press = > off (lighting level memorised)
- short press = > on (returns to memorised lighting level)
- long press = > increasing / decreasing variation of ligh-
ting level from the memorised lighting level (direction of
variation reversed on each press)
Peripheral devices
Cat. No. 841 37/87
Cat. No. 744 23 or
single non-illuminated
A
B
latching pushbutton
(unlimited quantity)
Cross-section = 1.5 mm 2 ,
max length = 200 m