Seav . LG 2215 Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
mend the blind is placed in an intermediate position so that you can see all confirma-
tion movements during the test procedures. After making sure the Wind sensor is oper-
ating correctly, you must remember to disable the Test.
Anemometer Test: manually rotate the Anemometer blades; at the same time, the
control unit will cause an upward movement lasting 5 seconds.
Programming: The control unit is supplied by the manufacturer with the Wired Wind
sensor test disabled. To enable the Test, proceed as follows: check that extended
menu 2 is enabled (T. MOT. and WIND SPEED LEDs start flashing simultaneously), use
the SEL button to navigate to the SENS. CODE LED when flashing and press the SET
button: the SENS. CODE LED remains lit in a constant manner and programming is
complete. Repeat the procedure to restore the previous configuration.
Important: for information on the Wireless Wind sensor test, please refer to the
Wireless Wind sensor manual.
R
ESET
To reset the default configuration of the control unit, press the SEL and SET buttons
simultaneously; all indicator LEDs will switch on and then off again immediately.
F
U
- I
OR THE
SER
MPORTANT
- The device should not be used by children or by individuals with reduced physical
or psychological abilities unless supervision is provided or instruction given on how
to operate it.
- Do not let children play with the device; keep radio controls out of their reach.
- CAUTION: Keep this instruction manual in a safe place and observe the important
safety instructions contained within it. Non-observance of these instructions may
lead to property damage and serious accidents.
- Examine the system frequently to check for any signs of damage. Do not use the
device if it needs to be repaired.
- We recommend carrying out the opening and closing operations of the blind or
rolling window shutter in visible conditions, ensuring no persons are in a dangerous
condition during movement.
Warning
All procedures which require the casing to be opened (such as wire connection, pro-
gramming, etc.) must be carried out during installation, by skilled staff only. For any
other procedure which requires the casing to be opened again (re-programming,
repairs or site modifications), please contact the technical assistance service.
F
I
- I
OR THE
NSTALLER
MPORTANT
- The control unit was designed to enable the installer to automate shutter move-
ment while adhering to the provisions set out by current legislation. Compliance with
these obligations and the implementation of the minimum safety requirements is the
responsibility of the installer.
We recommend installation is performed in full compliance with EN 60335-2-97
("Household electrical appliances and similar - Safety", part 2 "Particular require-
ments for drives for rolling shutters, awnings, blinds and similar equipment).
In this regard, realise the plant combined with this components control unit (motor,
mechanical parts, etc.) resulting conform in satisfying the necessary safety requi-
sites.
- The control unit must be permanently connected to the power supply network and
is not equipped with any type of 230 V a/c electric line sectioning device. The
installer is responsible for installing a sectioning device in the system. An omnipolar
switch with overheating category III must be installed. It must be positioned in such
a way that it is protected against accidental closures.
- For connections (power supply and motor output) we recommend the use of flex-
ible wires with an insulating sheath in harmonised polychloroprene (H05RN-F). The
wires should have a minimum cross-section of 0.75 mm
- Fasten the connection cables using the cable clamp supplied with the product kit.
- In choosing the motor to combine with the control unit, keep to the maximum
power indications contained in this manual.
For the radio receiver to operate correctly when two or more control units are used,
we recommend that you install the devices at least 3 metres away from each other.
If two or more control units are installed, we recommend only one Wireless Sensor
is used in order to avoid radio interference.
The below products:
LG2215 – LRS2215 – LRS2215 SET – LRH2215
conform to the specifications in the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
- 10 -
2
.
Rev. 3.0 13/06/2016

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lrs 2215Lrs2215 setLrh 2215

Tabla de contenido