4. CONNECTION
GROUNDING
The motor is fitted with an earth cable. Connect the other end to a safe earth.
The foot of the elevator is fitted with a threaded rod. You can connect it to a safe
ground.
CONNECTION TO THE COMPRESSED AIR SUPPLY
Air fitting 1/4" G
Level of filtration required : 5 µm
Connect the installation to the compressed air network (maximum 6 bar / 87 psi).
Adjust the lubricator to get a flow of one drop / minute when high speed or constant operating.
Note :
The air supply to the agitator is via a hose fitted with a quick release fitting that can be connected to
the elevator on motoraccording to the working stage.
When you have to rise or lower the cover, the air hose must be connected to the elevator; there
is no air on the motor of the agitator.
When the air hose is connected to the agitator motor and is in operation, you cannot rise or
flower the cover.
FLUID CONNECTION
Suction rod
Return rod
KREMLIN REXSON
Install a filter and a lubricator on the air supply of the agitator.
To ensure a correct operating and an optimum working life of the
agitator, the supply air must be clean (without water), filtered and
Install an FRL on the air supply of the agitator.
Elbow, model F 3/4 " G
Male 1/2 "
- 9 -
lubricated.