Only for IBV:
N° FLASH
ERROR
RED LED
1
Undervoltage
alarm
2
Overvoltage
alarm
3
Overcurrent
alarm
4
Overload alarm
5
Over
temperature
alarm
electronic card
6
Over
temperature
alarm
heatsink
7
Alarm Analog
8
Alarm eeprom
data
9
Alarm Timeout
communication
10
User alarm
11
STO alarm
(safe torque off)
If present
MAINTENANCE
ATTENTION: Before carrying out any maintenance, including cleaning, take the following
precautions:
make sure that the appliance is disconnected from the electrical mains (unplug from the electrical
outlet), making sure that the power supply can not be reactivated accidentally;
Make sure the appliance is completely cooled;
Use personal protection devices required by current regulations;
Always operate with appropriate equipment;
Once the maintenance / repair / cleaning operation has been completed, before putting the
appliance back into service, re-install all the protections and safety devices;
The voltage value of the device
has fallen below the minimum set
in parameter S602
The voltage value of the device
has exceeded the maximum value
set in parameter S603
The device has exceeded the
maximum current value set in
parameter S601
When the amount of energy
according to the I²t logic exceeds
that set by parameters S511 and
The device has reached and
exceeded the maximum allowed
temperature set in parameter
The motor has reached and
exceeded the maximum allowed
temperature set in parameter
Hardware malfunction, which can
input
not read the analog input
The data structure is not intact
Modbus communication
Alarm associated with an input
Specific input. Disable the power
so that the inverter is safe
CAUSES
S512
S604
S605
interrupted
SOLUTIONS
Alarm reset from keypad or input, or
automatically with autoreset function when
enabled
Alarm reset from keypad or input, or
automatically with autoreset function when
enabled
Alarm reset from keypad or input, or
automatically with autoreset function when
enabled
Alarm reset from keypad or input, or
automatically with autoreset function when
enabled
The alarm resets automatically when the
temperature of the device drops to 10 ° C
less than the threshold temperature set in
parameter S604
The alarm resets automatically when the
motor temperature drops to 10 ° C less than
the threshold temperature set in parameter
S605
Contact the manufacturer (the card must be
repaired)
The default values are restored
automatically. The different parameters must
be re-entered manually
Check connection
Eliminate the cause of the alarm
Eliminate the cause of the alarm