Cleaning and Sanitizing-Instructions

1. Rinse container thoroughly under running water. Add 8 ounces of clean rinse water
to container. Place container in normal operating position on mixer and run on
high speed for two (2) minutes. Empty container.
2. UNPLUG POWER CORD FROM ELECTRICAL OUTLET.
3. Loosen and remove thumbscrew. Snap-off on/off switch actuator knob.
4. Carefully remove stainless steel panel.
5. Wash, rinse, and sanitize thumbscrew, on/off switch actuator knob, stainless steel
panel, and container. Sanitize these parts by immersing in sanitizing solution for two
(2) minutes. Shake off excess moisture and allow parts to air dry.
6. Working from the top down, wash, rinse, and sanitize the portion of the mixer
housing situated directly over the container, and the portion of the spindle above the
agitator, using absorbent wiping cloths moistened with cleaning solution, rinse water
and sanitizing solution.
7. Reassemble panel, push on/off switch actuator knob, and thumbscrew to mixer
housing.
8. Wash, rinse, and sanitize the agitator and the bottom of the spindle as follows:
• Plug power cord into electrical outlet.
• Add 8 ounces of washing solution to container and place in normal operating
osition on mixer.
• Run on high speed for a minimum of two (2) minutes.
• Empty container, and repeat two-minute run with 8 ounces of rinse water.
• Empty container, and repeat two-minute run with 8 ounces of sanitizing solution.
• Empty container. Run motor for a few seconds with empty container in normal
operating position to spin off any excess moisture. Empty container. Do not rinse
container, spindle, or agitator after sanitizing is completed.
• Allow all parts to air dry.
Wash, rinse, and sanitize as outlined above prior to initial use, and whenever mixer
will not be used again within a period of one hour. Surfaces of the mixer housing which
are outside of the food-contact areas may be cleaned as required, using wiping cloths
moistened with cleaning solution, rinse water, and sanitizing solution.
UNPLUG POWER CORD FROM ELECTRICAL OUTLET BEFORE CLEANING
hOUSING. Prevent liquid from running into housing by wringing all excess moisture
from wiping cloths before using them. Washing solutions based on non-sudsing deter-
gents and chlorine-based sanitizing solutions having a minimum chlorine concentration
of 100 PPM are recommended. The following washing, rinsing, and sanitizing solutions,
or their equivalents, may be used.
Solution
Product
Washing:
Calgon
Rinsing:
Sanitizing:
Clorox
Bleach
(Not for waterjet cleaning)
®
Calgolac
®
Institutional
Dilution in Water
4 Tablespoons/Gallon
Plain Water
1 Tablespoon/Gallon
Temp.
hot 46˚C (115˚ F)
Warm 35˚C (95˚ F)
Cold 10˚C - 21˚C
(50˚ F - 70˚ F)