Horizontal levelling and vertical levelling
– Horizontal: Position the device on a level
surface or on a tripod.
– Vertical: Set the unit on its side feet. The
operator panel should be at the top.
– Press the "ON/OFF" switch
!
X/Y LEDs off: Automatic alignment
– The device levels itself automatically to within a range of ± 5°. During the
set-up phase, the laser flashes and the prism head remains stationary. When
levelling is complete, the laser lights up continuously and rotates at maxi-
mum speed. Refer also to the sections about "Sensor Automatic" and "ADS
Tilt".
The X/Y LEDs flash when the tilt angle of the device is too great
!
(outside 5°) and the laser as well as the prism head stops rotating.
The device must then be placed on a more even surface.
Positioning the vertical laser level
In vertical mode the laser level can be positioned exactly. "Sensor Automatic"
remains active and levels to the vertical laser level. Refer to the illustration
below.
!
The X/Y LEDs flashing alternately indicates that the maximum
adjustment range of 5° has been reached.