EN GLI SH
Troubleshooting
SITUATION
Unit does not turn on
Unit does not display objects;
says Pre-Scan Data Mapping
No materials detected or
difficult in detecting objects
Difficulty in detection of metal
Seemingly false metal
detection
Difficulty in scanning near
door or windows
Area of voltage detected is
larger than anticipated
Electrical voltage not
detected in area where it was
thought to be
Low confidence meter
reading
Received error message:
Too fast
Received error message:
Lost surface contact
Cannot get a center line to
appear
Screen freezes or won't
turn on
52
PROBABLE CAUSE
• No power to unit
• Unit is in process of
mapping scanned area
• Too narrow an area
mapped
• Difficulty in scanning
below special wall
condition
• Metal items too deep
• Metal items such as
jewelry are too close to
sensor area
• Double or triple studs are
common around doors
and windows
• Static charge may be
present on the wall
surface
• Wires are shielded by
metal conduit
• Wires are deeper than
76 mm (3")
• Wires are not live
• Cannot scan below
special wall condition
• Scanning in a non-straight
line
• Scanning too fast
• Difficulty scanning below
special wall condition
• Scanning too fast
• Hand-held radar scanner
lifted off wall surface
• Wall is thick or dense
• Software lockup
SOLUTION
• Make sure 10.8 V battery pack is fully charged
• Fully seat the 10.8 V battery pack in the handle
• Refer to Scanning Process section
• Re-map larger area
• Scan slowly
• Scan in a straight line
• Refer to Detection Through Special Surface
Conditions section
• Scan in both the horizontal and vertical
directions
• Scan in both horizontal and vertical straight
lines. Metal sensitivity is increased when the
metal object is parallel to the sensor.
• Remove jewelry & re-scan
• Detect outer edge instead
• Scan a smaller area
• Turn off the electrical circuit and identify metal
wire instead
• Place your free hand on the wall to drain static
• Review identified metal in scanning window to
determine metal conduit
• Plug an item into a wall outlet to verify live circuit
• Refer to Detection Through Special Surface
Conditions section
• Scan slowly
• Scan in a straight line
• Refer to Detection Through Special Surface
Conditions section
• Scan slowly
• Re-map area and repeat scanning
• Refer to Detection Through Special Surface
Conditions section
• Insert a small object (i.e., paper clip end) into
the reset button. The reset button is located on
the back surface, under the label. There is a
circle on the label indicating the reset location.