Omcan IC-CN-0012 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ICE CUBES ARE NOT SATISFACTORY
Problem
Cubes are too small
Cubes are too big
The cubes are partially
formed--have ragged
sides
Silica gel tubes
Floater valve
Wheel
Check part or point
Condenser
The ambient temperature The ambient temperature
Electronic controller
Refrigerant
Electronic controller
Sensor
The ambient and water
temperature
Water quality
Evaporator
Water distribution tube
The room temperature
Troubleshooting
The silica gel tubes
are distorted, leads to
blocking.
The floater valve
leaks. Leads to low ice
production.
The icemaker is not
properly leveled.
Possible Cause
The condenser is dirty or
the air grills are covered.
is too high.
The setting temperature
is high.
Refrigerant leaks.
The setting temperature
of Electronic controller is
low.
Temperature sensor
of the evaporator is
damaged.
The ambient temperature
and water temperature
are too low.
The water quality is poor.
Ice machine is dirty.
The water distribution
tube is partially blocked.
The room temperature is
out of the stated range,
the water pump stops.
17
Make the silica gel tubes
resile.
Repair or replace.
See installation.
Probable Correction
Clean the condenser.
Leave space around the
machine.
Adjust the ambient
temperature.
See the service manual
"adjust the size of ice
cubes".
Recharge.
See the service manual
"adjust the size of ice
cubes".
Replace the temperature
sensor.
Adjust the temperature.
Use a water-soften / filter
apparatus installed in
front of the water inlet
valve.
Clean and sanitize the ice
machine.
Clean the water
distribution tube.
Make the temperature
return within the stated
range.

Publicidad