The water distribution
tube doesn't spray
Harvesting ice is difficult
The evaporator is hot for
more than 4 minutes
Water line
Lines of the water pump
Water pump
Water distribution tube
Ice full probe
The room temperature
Hot gas valve
Ice mold of the
evaporator
Refrigerant
Ice machine
The ambient and water
temperature
Ice cubes size
Hot gas valve
Refrigerant
Electric controller
Troubleshooting
The water line leaks.
The lines of the water
pump are loose.
Water pump is damaged.
The water distribution
tube is blocked.
The ice full probe is
broken or can not turn
back to the normal
position.
The room temperature is
out of the stated range,
the water pump stops.
The hot gas valve is poor. Replace the hot gas
The hot gas valve is
damaged.
The ice mold is dirty, or
polishing degree is poor.
Refrigerant leaks.
Ice machine is not
properly leveled.
The ambient and water
temperature is too low.
The size is too big.
The lines of the hot gas
valve are loose.
Hot gas valve
performance poor or
broken.
Refrigerant leaks.
The electric controller is
incorrect.
19
Plug in again.
Plug in again.
Replace the water pump.
Clean the water
distribution tube.
Repair or replace the
probe.
Make the temperature
returns within the stated
range.
valve.
Replace the hot gas
valve.
Clean the ice mold, or
replace the evaporator.
Recharge.
Level the ice machine.
Adjust the temperature.
See "Adjust the ice cube
size".
Plug in again.
Replace the coil of the
hot gas valve if it is only
because of the coil.
Recharge.
Check the controller.