3/4" NPT
Pressure Relief
Field Wiring
Service Box
RJ-12
Control
Jack
10-1/4"
(26 cm)
Installation Requirements
Model
Ordering Information
Steam Generator Rating
Required Electrical Service
Dedicated Circuit Breaker #1
Dedicated Circuit Breaker #2
Main Electrical Service
Main Circuit Breaker
Control Kit
Steam Control Kit (one kit
required)
Product Information
Weight
Size
Electrical Rating
Water supply
Water supply Shut-Off Valve
Steam Line
Pressure Relief Valve (supplied)
Drain Line
Drain Valve
Sizing The Steam Room
Kohler Co.
3/8" NPT
Water In
17-5/8" (44.8 cm)
19-11/16" (50 cm)
K-1714-NA
18 kW (2-9 kW)
240 V, 50 A, 50/60 Hz
240 V, 50 A, 50/60 Hz
240 V, 100 A, 50/60 Hz
K-1698-PC OR
K-1838, K-638, and K-694 or K-695
42 lbs (19 kg), 21 lbs (9.5 kg ) each
18" (45.7 cm) L x 24" (61 cm) x 13" (33 cm)
240 V, 45 A, 50/60 Hz
3/8" copper line
3/8" NPT female
1/2" copper line (1/2" NPT thread)
3/4" NPT female thread
3/8" copper line
3/8" NPT female thread
480 cu. ft. (14 cu. m)
Minimum required access is
20" (50.8 cm) L x 13" (33 cm) H x
6-1/2" (16.5 cm) W.
1/2" NPT
Steam Outlet
12-1/2"
(31.8 cm)
K-1715-NA
22 kW (2-11 kW)
240 V, 70 A, 50/60 Hz
240 V, 70 A, 50/60 Hz
240 V, 140 A, 50/60 Hz
K-1698-PC OR
K-1838, K-638, and K-694 or K-695
240 V, 48 A, 50/60 Hz
3/8" copper line
3/8" NPT female
1/2" copper line (1/2" NPT thread)
3/4" NPT female thread
3/8" copper line
3/8" NPT female thread
635 cu. ft. (18 cu. m)
5
3/8" NPT Drain
6-1/8" (15.6 cm)
1059059-2-B