Rupes HE1500 Instrucciones Para La Puesta En Servicio, Uso Y Mantenimiento página 13

Turbina de aspiracion
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
HE900
TECHNICAL SPECIFICATIONS
WORKING VOLTAGE
MAX. ABSORBED CURRENT
SUCTION CAPACITY
ABSORBED POWER
MAX. DEPRESSION
FILTER CATEGORY
WEIGHT
NOISE LEVEL
BAG CAPACITY
WORKING PRESSURE
Connection to the electrical mains
After making sure the main switch (Fig. 4 D) is off:
Version 400 V - 50 Hz
- connect turbine cord 4 x 1.5 mm
breaker (20 Amp.) and line light (Fig. 4 C).
Version 230 V - 60 Hz
- connect the turbine cord 4 x 2.5 mm
cuit breaker (32 Amp.) and line light (Fig. 4 C).
The cord 2 x 1.5 mm
2
(Fig. 4 B) must be connected to the same electrical box
and connected to a HB or HF arm or EP3 unit with an electric or pneumatic tool
ignition system for remote starting. Ensuring grounding wire connections is very
important.
N.B.: Electrical connections materials are not standardly supplied and must be
provided by the general electric system installation technician.
These operations must be performed by a qualified electrician (according to
regulation CEI 64-8 in accordance with legal decree 46-90).
Connecting to the compressed air system
Assemble the pressure regulator (9), respecting the direction of the arrow, com-
plete with its pressure gauge (4).
The compressed air supply line (Ø 3/4") must be regulated through knob (9A) to
a maximum pressure of 6 bar (see pressure gauge 4). Carry out the adjustment
and lock knob (9A) by pushing it as far as it will go.
IMPORTANT: Only filtered dry air must be used.
This operation must be carried out by suitably qualified personnel.
MACHINE USE
Turn on the main switch (Fig. 4 D).
Manual mode
In manual mode, the turbine will operate continuously.
To interrupt the continuous operation, press button (33) to pass to AUTOMATIC
mode, or turn the knob (27) to OFF to switch the shut down the machine.
Automatic mode
In AUTOMATIC mode, the turbine is started by remote control.
This system must be connected to HB o HF arms or a EP3 power unit equipped
with an automatic turbine start-up system when electric or pneumatic tools are
switched-on.
When the tool is switched off, the turbine will continue to operate for 1 minute.
After 1 minute it will then shut-down and remain on stand-by waiting for the next
start-up.
Starting (400 V - 50 Hz model)
- Turn the knob (27) to ON to switch the turbine on, LEDS 28-29-30-31 will light-
up in sequence. LEDS 30-31 will then switch off automatically;
- LED 29 lights permanently to indicate that the turbine is in AUTOMATIC mode,
while LED 28 lights permanently to indicate that the turbine is powered;
- Select the operating mode (MANUAL or AUTOMATIC) by pressing button (33).
Start-up (version 230 V. - 60 Hz)
- Turn the knob (27) to ON to switch the turbine on, LEDS 28-29-30-31 will light-
up in sequence. LEDS 30-31 will then switch off automatically;
- LED 29 lights permanently to indicate that the turbine is in AUTOMATIC mode,
while LED 28 lights permanently to indicate that the turbine is powered;
- Select the operating mode (MANUAL or AUTOMATIC) by pressing button (33)
Checking the direction of rotation of the turbine motor
The pump has a tree-phase motor and is designed to rotate in both directions:
during the installation of the turbine and initial start-up, check that the air flow mat-
ches the direction shown on the adhesive arrows.
Otherwise, reconnect the power cord, inverting two phases.
14
three-phase 230Vca-60Hz / three-phase 400 Vca-50Hz
20 A (230 V)
12 A (400 V)
550 m
3
/h
5500 W - 7.5 HP
2900 mm/H
O = 28,4 kPa
2
5.2 m
2
185 Kg
71 dB(A) LpA
50 lt
6 bar
2
(Fig. 4 A) to an electrical box with a circuit
2
(Fig. 4 A) to an electrical box with a cir-
HE1500
TECHNICAL SPECIFICATIONS
WORKING VOLTAGE
three-phase 230Vca-60Hz / three-phase 400 Vca-50Hz
MAX. ABSORBED CURRENT
SUCTION CAPACITY
ABSORBED POWER
MAX. DEPRESSION
FILTER CATEGORY
WEIGHT
NOISE LEVEL
BAG CAPACITY
WORKING PRESSURE
Connection to the electrical mains
After making sure the main switch (Fig. 4 D) if off:
Version 400V - 50 Hz
- connect the turbine cord 4 x 2.5 mm
cuit breaker (32 Amp.) and line light (Fig. 4 C).
Version 230 V - 60 Hz
- the electrical box with 60 Amp. circuit breaker and line light are already installed
and connected to the machine with cords 4 x 10 mm
4 B) must be connected to the same electrical box and connected to a HB or HF
arm or EP3 unit with an electric or pneumatic tool ignition system for remote
starting. Ensuring grounding wire connections is very important.
N.B.: Electrical connections materials are not standardly supplied and must be
provided by the general electric system installation technician.
These operations must be performed by a qualified electrician (according to
regulation CEI 64-8 in accordance with legal decree 46-90).
Connecting to the compressed air system
Assemble the pressure regulator (9), respecting the direction of the arrow, com-
plete with its pressure gauge (4).
The compressed air supply line (Ø 3/4") must be regulated through knob (9A) to
a maximum pressure of 6 bar (see pressure gauge 4). Carry out the adjustment
and lock knob (9A) by pushing it as far as it will go.
IMPORTANT: Only filtered dry air must be used.
This operation must be carried out by suitably qualified personnel.
MACHINE USE
Turn on the main switch (Fig. 4 D).
Manual mode
In MANUAL mode, the unit operates continuously:
- when manual mode is selected, turbine 1 is started up immediately;
- if push button (33) is pushed a second time, turbine 2 is started up;
- if push button (33) is pushed a third time, turbine 1 is cut off;
- if push button (33) is pushed a fourth time, turbine 2 is cut off and the unit swit-
ches to "automatic" mode.
Turn the knob (27) to OFF to switch the shut down the machine.
Automatic mode
In automatic mode, the turbine is started by remote control. The unit may be star-
ted up in one of two ways, depending on the conditions in effect on the HB or HF
arms or EP3 units with automatic electro-pneumatic systems:
1) The commutator (MAN, "0", AUT) is set to MAN:
- turbine 1 is started up immediately;
- turbine 2 is started up when required, depending on the strength of the vacuum
created in the suction pipe. If the vacuum is high, turbine 2 is not started up; if
it is low, turbine 2 is started up. If turbine 2 has been started up and the vacuum
in the suction pipe exceeds the set value, turbine 2 is stopped.
To turn off turbine 1, set the switch to "0", and turbine 1 will go off after 1 minu-
te, remaining on standby.
2) The commutator (MAN, "0", AUT) is set to AUT:
- turbine 1 is started up whenever an electrical or pneumatic tool is started up;
- turbine 2 is started up when required, depending on the strength of the vacuum
created in the suction pipe. If the vacuum is high, turbine 2 is not started up; if
it is low, turbine 2 is started up. If turbine 2 has been started up and the vacuum
in the suction pipe exceeds the set value, turbine 2 is stopped.
To turn off turbine 2, turn off the tools. Turbine 2 will go off after 1 minute, remai-
ning on standby. Turn the knob (27) to OFF to switch the shut down the machine.
Starting (400 V - 50 Hz model)
- Turn the knob (27) to ON to switch the turbine on, LEDS 28-29-30-31 will light-up
in sequence. LEDS 30-31 will then switch off automatically;
- LED 29 lights permanently to indicate that the turbine is in AUTOMATIC mode, whi-
le LED 28 lights permanently to indicate that the turbine is powered;
- Select the operating mode (MANUAL or AUTOMATIC) by pressing button (33).
Start-up (version 230 V. - 60 Hz)
- Turn the knob (27) to ON to switch the turbine on, LEDs 28-29-30-31 light on
40 A (230 V)
24 A (400 V)
550+550 m
3
/h
11000 W - 15 HP
2900 mm/H
O = 28,4 kPa
2
8 m
2
270 Kg
74 dB(A) LpA
50 lt
6 bar
2
(Fig. 4 A) to an electrical box with a cir-
2
. Cord 2 x 1.5 mm
2