Descargar Imprimir esta página

Kohler sok K-1188-RE Diagrama De Instalación página 2

Ocultar thumbs Ver también para sok K-1188-RE:

Publicidad

Idiomas disponibles

Idiomas disponibles

No change in measurements with drain
shown. (K-7193 or K-7193M)
31-1/2" (80 cm)
2" (5.1 cm)
1" (2.5 cm)
Product Information
Right drain
Right drain, with lights
Left drain
Left drain, with lights
Fixture*:
basin area
Bathing well
45" (114.3 cm) x
25-1/2" (64.8
cm)
water depth
To overflow
23-1/2" (59.7
cm)
Cut-out
73-1/2" (186.7 cm) x 39-1/2" (100.3 cm)
* Approximate measurements for comparison only.
Rating
Bath
1.5 hp
Heater
4 kW
* Approximate measurements for comparison only.
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with a Class A
Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage
Circuit-Breaker (ELCB):
Pump/control/heater
1019731-1-C
Pump/Control Access
15" (38.1 cm) H x
40" (101.6 cm) W Min
25"
(63.5 cm)
K-1188-RE
not shown
K-1188-C1
shown
K-1189-RE
not shown
K-1189-C1
not shown
top area
63" (160 cm) x
31-1/2" (80 cm)
capacity
142 gal (537.5
L)
V
A*
240
4
240
17
208-240 V, 20 A,
50/60 Hz
75" (190.5 cm)
63" (160 cm)
1" (2.5 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
Notes
Install this product according to the installation guide.
Two separate 240 V electrical services required; one for the
pump/control, and another for the heater.
Floor support under whirlpool must provide for a minimum of
2000 lbs (907.2 kg).
Consult local and national codes for minimum air gap
requirements when installing a spout on the faucet deck.
weight
Hot water supply should be 70% of capacity or greater.
275 lbs
Installations will vary.
(124.7
kg)
Unit must be filled through the bathing well.
Fixture conforms to ANSI Standard Z124.1. All dimensions are
nominal.
2
41"
(101.4 cm)
20-1/2"
(52.1 cm)
7-1/4"
(18.4 cm)
16-13/16"
(42.7 cm)
5-1/2" (14 cm)