Model/Type
Supply voltage:
Fuse (slow-blow):
Power consumption:
Cutting parameters:
Duty cycle (DC%):
Cutting thickness max.:
Operating pressure:
Air consumption:
Burner length:
Earth cable:
Power cable:
Protection class:
Insulation material class:
Weight:
Dimensions (L × W × H):
Standards:
LOCATION AND HANDLING OF THE MACHINE
Select a place that is well ventilated and free from dust, smoke, and gas.
■
Make sure that nothing prevents the flow of cooling air through the front and rear openings
■
of the machine.
Make sure that the cooling air can circulate freely at the inlet and outlet.
■
Before transport of any kind, switch off the mains switch and disconnect from the mains.
■
When transporting, make sure that no cables are damaged.
■
MAINS CONNECTION
Only connect up the machine to the mains using a mains connection which supplies the
■
required supply voltage and frequency, see type plate.
Make sure that the mains connection is connected to the earth of the mains system and
■
meets the requirements of IEC.
ArCut AC 71
400 V 50/60 Hz
16 A
8 kVA
20 – 75 A
75 A / (40 %)
45 A (100 %)
30 mm
5 – 6 bar
250 l/min (4.8 bar)
6 m
5 m
5 m / 5 x 2.5 mm²
IP 22 S
H (180 °C)
30.7 kg
530 × 255 × 480 mm 600 × 255 × 480 mm
EN 60974-1
EN 50192
EN 60974-10
ArCut AC 101
400 V 50/60 Hz
32 A
14 kVA
20 – 105 A
16 A
105 A / (100 %)
40 mm
5 – 6 bar
330 l/min (5.5 bar)
6 m
5 m
5 m / 5 x 6 mm²
IP 22 S
H (180 °C)
42.4 kg
EN 60974-1
EN 50192
EN 60974-10