Preparation
Make three or more holes in the ceiling or wall for the screws that are to be used to secure the main unit. If embedding the input power
wire and video out cable, make a hole for these cables to be passed through also.
Surface unit installation
- Releasing the dome assembly (G) by turning in counter clockwise direction.
- Take out the camera body (F) and the metal holder (E).
- Align the housing assembly (C) with the screw holes that have been prepared, and then secure it by tightening the four screws (D)
- Pass the input power wire (A) and video out cable (B) through the hole made for that purpose.
- Replace the camera body (F) and the metal holder (E) back into position, by securing it with the dome assembly (G)
(turning in clockwise direction).
- Determine the lens position in accordance with the location of the objects to be viewed, positioning it by turning slowly the
viewing hole on top of the camera body (F) (which is the round shaped ball object).
- Lens view may be adjusted by turning slowly the viewing hole on top of the camera body (F).
In-ceiling unit installation
- Pass the input power wire (A), the video out cable (B) and the housing assembly (C) through the hole made for that purpose.
- Align the dome assembly (D) with the screw holes that have been prepared,and then secure it by tightening the three screws (E).
- Determine the lens position in accordance with the location of the objects to be viewed, positioning it by turning slowly the
viewing hole on top camera body (which is the round shaped ball object).
- Lens view may be adjusted by turning slowly the viewing hole on top of the camera body.
Specifications
Sensor
Picture element
TV system
Horizontal resolution
Day/Night
ICR
Minimum illumination
S/N ratio
Auto electronic shutter
Auto iris control
Gamma characteristic
Auto gain control
Auto white balance
Back light compensation
Synchronous system
Lens mount
Video output
Infrared lamps irradiation distance
IP degree
Power supply
Input current
Operating temperature
Dimensions
SAFETY PRECAUTIONS
•
Please do not directly touch the sensor element.
If necessary, use a soft cloth moistened with alcohol to wipe off any dust.
•
Please be extra careful not to shake the camera
•
Please avoid places where there is direct sunlight
•
When using this camera in places where the lighting differs greatly, please use an auto iris lens.
•
Please avoid places where temperatures exceed 50° C or more, high humidity or where direct rain drops hit, frequent
vibrations, or shocks occur.
•
During the night, if a minimum brightness of 0.2 Lux can not be achieved, install appropriate light fixtures.
•
When the camera is not used, keep the lens or the lens cap attached to protect the sensor.
Warning
- The installation and calibration of this camera must be carried out by highly skilled personnel.
- Do not open the camera: there may be a risk of electric shock.
- Low voltage cameras must be powered by a power supply unit with stabilized voltage.
This range of cameras has been created for CCTV applications and not for other uses.
Use these cameras only for the following temperature conditions: from (-10) – (+50) °C.
Do not use the cameras with voltages different from the ones specified.
1/3" Color Sony Super HAD II
500 (H) x 582 (V)
PAL
420TV Lines
No
No
0,05 Lux / F 1,2
> 48 db
Yes
Fixed
0.45
Yes
Yes
No
Internal synchronisation
3,7 mm F 2.0 cone lens
1 Vpp / 75 Ω
No
No
DC 12V
117 mA max
-10°C to 50°C
Diameter 75 mm; Height 45 mm