Protective Gear
Personal Protective Equipment (PPE) must comply with the
American National Standards Institute's ANSI Z87.1-1989 standard
if purchased after July 5, 1994, or ANSI Z87.1-1968 or with the
standard of the country in use.
• Eye and face PPE shall be distinctly marked to facilitate
identification of the manufacturer. (1910.133[a][4]).
• The following minimum requirements must be met by all
protective devices. Protectors shall:
- Provide adequate protection against the particular hazards
for which they are designed
- Be of safe design and construction for the work to be
performed
- Be reasonably comfortable when worn under the designated
conditions
- Fit snugly and not unduly interfere with the movements
of the wearer
- Be durable
- Be capable of being disinfected
- Be easily cleanable
- Be distinctly marked to facilitate identification only
of the manufacturer
THE USE OF EYEWEAR PROTECTION IS RECOMMENDED
WHEN USING THIS DEVICE.
ALWAYS USE APPROPRIATE PPE, LISTED ON THE CLOROX-
APPROVED PRODUCT'S SAFETY DATA SHEET (SDS).
CLOROX SDSs CAN BE FOUND AT
WWW.THECLOROXCOMPANY.COM/BRANDS/SAFETY-
INFORMATION/SDS/.
IMPORTANT SAFETY PRECAUTIONS
When using an electrical appliance, it is important to understand
that some circuits are electrically live, even when the power switch
is in the off position. Basic safety precautions should always be
followed to reduce the risk of burns, fire, electrical shock, injury
and/or death.
Power Connection
Our power plug must be used with a three-pronged, grounded
outlet, rated for no less than 15A service. Always verify before
product use. This appliance is for use on a nominal 120V/60Hz
circuit with a verified ground plug. Check with a qualified electrician
to ensure you have the correct electrical service and grounding.
GROUNDING
PIN
*120-volt grounded connectors shown. 220/240-volt grounded connectors will
differ in shape.
Grounding Instructions
This appliance must be grounded. In the event of malfunction
or breakdown, grounding provides a path of least resistance
for an electric current to reduce the risk of electric shock. This
appliance is equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances. Never use an
adapter with this product.
DANGER: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The conductor with
insulation having an outer surface that is green, with or without
yellow stripes, is the equipment-grounding conductor. If repair or
replacement of the cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal. Check with a
qualified electrician or serviceman if the grounding instructions are
not completely understood or if in doubt as to whether the appliance
is properly grounded. Do not modify the plug provided with the
appliance — if it will not fit the outlet, have a proper outlet installed by
a qualified electrician. Never use an adapter with this product.
Extension Cord
Clorox provides a 25-foot (7.6m) extension cord with each Total
360® Electrostatic Sprayer and strongly recommends that you use
this approved extension cord. Make sure your extension cord is in
good condition. Inspect cords periodically and replace if damaged.
If an alternate extension cord is used, be aware that an undersized
extension cord will cause a drop of in-line voltage, which
could result in a loss of power, damage to the product and/or
overheating. Always use a sufficiently rated extension cord.
IMPORTANT: Clorox recommends using a 12/3 gauge extension
cord, no longer than 100 feet (30.5m). Additionally, Clorox also
recommends the use of a GFCI (ground fault circuit interrupter)
power outlet or extension cord. When equipped on the extension
cord, always position the GFCI toward the power outlet.
COVER OF
GROUNDED
OUTLET BOX*
EN