tau MEC 1000 Manual Del Usuario página 9

Ocultar thumbs Ver también para MEC 1000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

12V POWER SUPPLY
LOGIC WITH MICROPROCESSOR
ELECTRONIC ADJUSTMENT OF MOTOR TORQUE
END OF MANEUVER MOTOR DECELERATION
DOOR OPENING AND CLOSING DELAYS
WORK AND PAUSE TIME SELF-LEARNING FUNCTION
LED DISPLAY OF INPUT STATUSES
12V INPUT PROTECTION WITH FUSE
12V OUTPUT PROTECTION WITH FUSE
BUILT-IN BATTERY CHARGER CIRCUIT
CONNECTIONS TO THE TERMINAL BOARD
1-2
OPTIONAL: 12 VDC POWER SUPPLY supplementary voltages INPUT
+ Terminal 1, - Terminal 2. Contacts may only be used with the stabilizer card.
3-4
12 VDC 6Ah DRY BATTERY input,
The battery powers the panel for 24 h in the standby mode and approx. 20 minutes if the motor is
working
+ Terminal 3, - Terminal 4.
5-6
12 V OUTPUT 12 VDC outlet, max. 20 W.
For power supply to RECEIVERS and PHOTOCELLS, etc
Protected by a 3,15A fuse (5x20).
+ Terminal 5, - Terminal 6.
7-8
M1 motor output 12 VDC max. 50 W.
Connect the motor with the electric lock. Delayed action during closing (this delay can be adjusted
with dip-switches 7A and 8A). Protected by a 12 Ah fuse.
9-10
M2 motor outlet 12 VDC max. 50 W.
Connect the motor without the electric lock. Delayed action during opening. (Fixed delay).
Protected by a 12 Ah fuse.
11-14
12 VDC output for FLASHING LIGHT, max. 20 W. + Terminal 11, -Terminal 14 (Common=14).
12-14
INDICATOR LIGHT OUTPUT 12 VDC max. 15 W.
This lights up at the beginning of the opening phase until the gate is totally closed.
+ Terminal 12, -Terminal 14 (Common=14).
13-14
ELECTRIC LOCK OUTPUT 12 VDC max. 15 W.
This is active for 1 second before and 3 seconds after the close delay door (M1) starts opening.
DIP 2B can be used to select the courtesy light which remains on for approx. 3 minutes after the
maneuver has terminated. + Terminal 13, - Terminal 14 (Common=14).
15-17
PEDESTRIAN pushbutton input (Normally Open contact); this does exactly the same job as the
OPEN/CLOSE pushbutton; DIP 1A is used to control this function. (Common=17).
If the card is configured for 2 motors the pedestrian impulse completely opens the M1 motor door.
If it is configured for one motor the pedestrian open function can be programmed as preferred.
(approx. 30 maneuvers).

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mec 2000

Tabla de contenido