Maintenance

Figure 12 - Choke Position
CHOKE LEVER
LEFT = CHOKE
RIGHT = RUN

2.8 STOPPING THE ENGINE

1. Shut off all loads, then unplug the electrical loads from
generator panel receptacles. Never start or stop the engine
with electrical devices plugged in and turned on.
2. Let engine run at no-load for several minutes to stabilize the
internal temperatures of engine and generator.
3. Move the ON/OFF switch to OFF position.
4. Close fuel valve.

2.9 LOW OIL LEVEL SHUTDOWN SYSTEM

The engine is equipped with a low oil level sensor that shuts down
the engine automatically when the oil level drops below a specified
level. If the engine shuts down by itself and the cylinder has
sufficient fuel, check engine oil level.

2.9.1 SENSING LOW OIL LEVEL

If the system senses a low oil level during operation, the engine
shuts down. The engine will not run until the oil has been refilled
to the proper level.

3.1 MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required
when operating in adverse conditions noted below.
Check Oil Level
Change Oil ‡
Check Valve Clearance
Service Air Filter
Replace Spark Plug
‡ Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
***
Check valve clearance and adjust if necessary after first 50 hours of
operation and every 300 hours thereafter.
10
At Each Use
*Every 100 hours or Every Season
***Every Season
** Every 50 hours or Every Season
Every Season

3.2 PRODUCT SPECIFICATIONS

3.2.1 GENERATOR SPECIFICATIONS

Rated Power .........................................................................3.25 kW**
Surge Power .............................................................................3.75 kW
Rated AC Voltage ......................................................................120/240
Rated AC Load
Current @ 240V .............................................................13.5 Amps**
Current @ 120V .............................................................27.0 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
Operating Temperature Range................. 0° F (-17° C) to 110° F (43° C)
** Maximum wattage and current are subject to, and limited by, such factors
as fuel Btu content, ambient temperature, altitude, engine condition, etc..
Maximum power decreases about 3.5% for each 1,000 feet above sea level;
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F)
ambient temperature.

3.2.2 ENGINE SPECIFICATIONS

Displacement .............................................................................. 212 cc
Spark Plug Type ................................................................ NGK BPR7ES
Spark Plug Part No. ........................................................... 0J00620106
Spark Plug Gap .............................0.028-0.031 inch or (0.70-0.80 mm)
Fuel Capacity ........................................................................ 20 Pounds
Oil Type.................. See Chart in "Before Starting the Generator" Section
Oil Capacity ................................................................. 0.6 L (0.63 Qts.)
Run Time at 50% Load ...............................................................9 Hours

3.2.3 EMISSIONS INFORMATION

The Environmental Protection Agency (EPA) requires that this
generator comply with exhaust emission standards. The engine
used in this generator is certified to meet the applicable EPA
emission levels. It is important to follow the maintenance
specifications provided in this manuals to ensure that the engine
complies with the applicable emission standards for the duration
of the engine's life. The emission control system on this generator
consists of the following:
• Air Induction system
Intake Pipe/Manifold
Air Cleaner
• Exhaust System
Exhaust manifold
Muffler
The Emissions Compliance Period referred to on the Emissions
Compliance Label indicates the number of operating hours
for which the engine has been shown to meet EPA emission
requirements.
Ignition System
– Spark Plug
– Ignition Coil
Fuel System
– Carburetor
– Regulator