3.7 LONG TERM STORAGE
1. Drain oil from crankcase after the engine cools down. Refill
with recommended grade.
2. Remove spark plug and pour about 1/2 ounce (15 ml) of
engine oil into the cylinder. Cover spark plug hole with rag. Pull
the recoil starter a couple times to lubricate the piston rings
and cylinder bore.
Avoid spray from spark plug hole when
cranking engine.
3. Install and tighten spark plug. Do not connect spark plug wire.
4. Clean the generator outer surfaces. Check that cooling air
slots and openings on generator are open and unobstructed.
5. Store the unit in a clean, dry place.
3.8 OTHER STORAGE TIPS
• If possible, store the unit indoors and cover it to give protection
from dust and dirt. BE SURE TO CLOSE THE VALVE ON THE
FUEL TANK.
• Cover the unit with a suitable protective cover that does not
retain moisture.
NEVER cover the generator while engine and
exhaust areas are warm.
Maintenance