CLEANING AND CARE
Wipe off powder coated surfaces with soft,
Ÿ
moist rag. Do not clean heater with cleaners
that are combustible or corrosive.
Remove debris from the burner to keep it clean
Ÿ
and safe for use.
Cover the burner unit with the optional
Ÿ
protective cover when the heater is not in use.
PARTS AND SPECIFICATIONS
A. Construction and characteristics
Transportable terrace/garden heater with
Ÿ
tank housing.
Casing in steel with powder-coating or in
Ÿ
stainless steel.
Gas hose connections with metal clamp
Ÿ
(screw caps for Germany).
Heat emission from reflector.
Ÿ
B. Specifications
Use propane,butane or their mixtures gas
Ÿ
only.
Max. wattage: 11000 watts
Ÿ
Min. wattage: 5000 watts
Ÿ
Consumption:
Ÿ
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
GAS PRESSURE
OF REGULATOR:
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
GAS PRESSURE
OF REGULATOR:
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
GAS PRESSURE
OF REGULATOR:
Using the proper regulator according to
Ÿ
outlet pressure of regulator as showed as
showed in the table above
Table of injector
APPLIANCE CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
TOTAL HEAT INPUT:
(Hs): (Qn)
INJECTOR SIZE:
I
3B/P(30)
Butane, propane or their mixtures
30 mbar
10 kW (G30:800 g/h; G31:786 g/h)
1.75 mm for main burner
0.22 mm for pilot burner
The hose and regulator assembly must
Ÿ
conform to local standard codes.
Regulator outlet pressure should meet the
Ÿ
corresponding appliance category in B.
Specification.
The appliance requires approved hose in 0.6m
Ÿ
length.
13
I +
(28-30/37)
3
Butane
28-30 mbar
28-30 mbar
I
3B/P(30)
Butane, propane or
their mixtures
30 mbar
30 mbar
I
3B/P(37)
Butane, propane or their mixtures
37 mbar
37 mbar
I +
(28-30/37)
3
Butane
28-30 mbar
10 kW (G30:728 g/h; G31:715 g/h)
1.75 mm for main burner
0.22 mm for pilot burner
I
3B/P(50)
Butane, propane or their mixtures
Butane, propane or their mixtures
50 mbar
1.55 mm for main burner
1.60 mm for main burner
0.22 mm for pilot burner
0.22 mm for pilot burner
ENG
Propane
37 mbar
37 mbar
I
3B/P(50)
Butane, propane or
their mixtures
50 mbar
50 mbar
Propane
37 mbar
I
3B/P(37)
37 mbar