model
AC output voltage
Continuous AC
output power
Maximum AC output
range surge power
AC output
frequency (nominal)
AC output waveform
DC output
voltage range
DC input
voltage range
Battery drain with
no AC load
Low battery alarm
trigger point
Low battery shutdown
point (nominal)
Low battery resume
point (nominal)
High battery shutdown
point (nominal)
Fuse (Not User
Serviceable)
Efficiency (maximum)
36
InverterManual_012411.indd 36
All manuals and user guides at all-guides.com
1000w
1500w
105V ~
105V ~
125V AC
125V AC
1000W
1500W
2000W
3000W
59 ~ 62Hz
59 ~ 62Hz
Modified
Modified
sine wave
sine wave
5V DC
5V DC
(500ma)
(500ma)
12.8
12.8
~13.2V DC
~13.2V DC
0.6A (at a
0.8A (at a
12V input)
12V input)
11±0.3V
11±0.3V
DC
DC
10.5±0.3V
10.5±0.3V
DC
DC
12.0V
12.0V
15.5V
15.5V
25A mini
30A mini
slip fuse x6
slip fuse x7
85%
85%
2000w
3000w
105V ~
105V ~
125V AC
125V AC
2000W
3000W
4000W
6000W
59 ~ 62Hz
59 ~ 62Hz
Modified
Modified
sine wave
sine wave
5V DC
5V DC
(500ma)
(500ma)
12.8
12.8
~13.2V DC
~13.2V DC
1A (at a
1A (at a
12V input)
12V input)
11±0.3V
11±0.3V
DC
DC
10.5±0.3V
10.5±0.3V
DC
DC
12.0V
12.0V
15.5V
15.5V
30A mini
30A mini
slip fuse x10
slip fuse x16
85%
85%