Step 4.
Insert the mixer in reverse
order of steps 2 and 3 in the
Disassembly Procedure section.

5.3. Operation procedure

Step 1.
Turn on the power supply (plug it in).
Step 2.
Remove the lid and pour the drink prepared according to the
flow chart into the bowl. The heating temperature should vary
between 30°C and 90°C. It is recommended to set the
temperature to 40-50 °C.
Step 3.
To start the machine, press the main switch. LED lights up
when the machine is running. LED goes out when the machine
is off
Step 4.
Turn on the power and press switch A; the machine starts
working, and LED C lights up. Press switch A again to start the
heating element, LED D lights up. Press switch A until LEDs C
and D go out. Then press and hold down thermostat B until the
temperature rises. Release thermostat B as soon as it reaches
the desired temperature.
A: heating and mixing switch
B: thermostat
C: mixing LED
D: heating LED
24