Quick Installation

Unplug the computer's power
1
cord from both AC outlet and
the computer's AC input.
Insert the female plug of the
2
computer's cord into the UPS's AC
input.
Insert the male plug of the
A
computer's cord into AC outlet.
NOTE! After you plug the UPS into a live AC outlet, the UPS will
turn ON automatically. See "ON/OFF/STANDBY" Button
description in the Basic Operation section if you want to place the
UPS in any mode other than ON.
3
Using one of the jumper cords
supplied with the UPS, insert
the cord's female plug into
computer's AC input . Insert
the cord's male plug into any of
UPS's female output receptacles.
Plug additional equipment into
4
the UPS.*
Use one of the additional jumper cords supplied with
the UPS, or order additional jumper cords from
Tripp Lite. Call (773) 869-1234; order part # P004-006.
* Your UPS is designed to support only computer equipment. You
will overload the UPS if the total VA ratings for all the equipment you
connect exceeds the UPS's output capacity (see Specifications). To
find your equipment's VA ratings, look on their nameplates. If the
equipment is listed in amps, multiply the number of amps by 230 to
determine VA. (Example: 1 amp × 230 = 230 VA). If you are unsure if
you have overloaded the UPS's outlets, see "OUTPUT LOAD
LEVEL" LED description.