SPIT DWS 225 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Remove the motor, while ensuring the first drive shaft, located in the column, remains
attached to the second drive shaft. Remove the two brush holder screws. Lift away the
two carbon brush holders and remove the carbon brushes.
NOTE: When putting the carbon brushes back into the carbon brush holders, it is
essential that both flanges go back inside the holder.
NOTE: To reinstall the same brushes, first make sure the brushes go back in the
way they came out. Otherwise a break-in period will occur that will reduce motor
performance and increase brush wear.
Replacing is the reverse of removal.
Replace the brushes in the holders then put the holder in place in the housing and
secure the screws.
When replacing the 2 motor and handle cover halves take great care that all wires are
in place and not in a position to be pinched when it is retightened. It is recommended
that, at least once a year, you take the tool to a Spit authorized service centre for a
thorough cleaning and lubrication.
If the replacement of the power supply cord is necessary, this has to be done by the
manufacturer or their agent in order to avoid a safety hazard.
Dispose of your appliance, accessories and packaging in an environment-friendly
manner.
"The English version of this manual is the only legal version."
8
8

Publicidad

Tabla de contenido
loading

Productos relacionados para SPIT DWS 225

Tabla de contenido