Thermal Protection - Stanley VIP MULTI 160 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
MOG INSTALLATION (NO GAS) (FIG A-3):
1.
Switch off the welding machine.
2.
Connect the gas / nogas cable (C) to the negative "-" negative socket and
the earth clamp connector (B) to the positive "+" positive
3.
socket. Perform steps 5-11 as per MIG / MAG installation.
INSTALLATION MMA (FIG A-4):
1.
Turn off the welding machine
2.
Connect the dinse connector of the earth clamp (B) to the negative "-" dinse
socket and the dinse connector of the electrode holder (I) to the positive "+"
socket on the welding machine. Insert the electrode into the electrode
holder (I); the diameter and type must be chosen according to the welding
current and to the thickness and type of piece to be welded.
3.
Turn on the welding machine.
4.
Press the (P5A) [MMA/TIG LIFT/MIG] key until the MMA (P6A) lights up.
Turn the right knob (P1) to set the welding current.
5. To use the various types of electrodes follow the polarities indicated on the
package containing the electrodes.
Caution. At this moment a voltage will be present on the welding clamps.
Fig. A-4
TROUBLESHOOTING
The thread does not
advance when the drive
wheel turns
Thread feeding: presence
of clicks or intermittence
Arc off
Porous welding cord
The machine suddenly
stops operating after
prolonged use
Fig. A-3
I
REASONS
Dirt on the tip of the thread guide
nozzle
The friction of the decoiler is
excessive
Defective torch
Defective contact nozzle
Burns in the contact nozzle
Dirt on the groove of the drive
wheel
Furrow on the worn drive wheel
Bad contact between mass clamp
and workpiece
Bad contact between mass clamp
and workpiece
Wrong distance or inclination of
the torch
Too little gas
Wet parts
The machine has overheated due
to excessive use and thermal
protection has intervened
INSTALLATION TIG LIFT AUTOMATIC (FIG A-5):
1.
Turn off the welding machine
2.
Connect the dinse connector of the earth clamp (B) to the positive "+" and
"dinse" connector of the torch (H) to the negative "-" socket of the welding
machine.
3.
Connect the torch gas pipe connector to the cylinder (A).
4.
Turn on the welding machine.
5.
Press the (P5A) [MMA/TIG LIFT/MIG] key until the TIG LIFT LED
(P6B) lights up. Turning the knob (1) to set the current during the
welding process.
Fig. A-5

THERMAL PROTECTION

If the machine is used for hard work cycle, the thermal protection device will
protect the machine from over heating. The yellow LED ON indicates that
the thermal protection is on. (P8).
MAINTENANCE
The all maintenance services must be done from qualified
personnel in compliance to the norm (IEC 60974-4).
Blow with air
Loosen
Check the thread guide sheath
Replace
Replace
To clean
Replace
Tighten the clamp and check
Clean or replace contact and guiding nozzles
Clean the encrustations
The distance between the torch and the piece must
be 5-10 mm;
The inclination not less than 60 ° with respect to the
piece.
Increase the quantity
Dry with a hot air gun or other means
Allow the machine to cool for at least 20-30 minutes
5
Touch the piece with the electrode
Lift the electrode from the piece
about 2-5 mm
REMEDY

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

460276

Tabla de contenido