3. Open the jaws and center one of the conductor. Make sure the conductor is
placed at center of the jaw. Only one conductor at each time can be measured.
The measured value shows on the display.
4. Push RELΔ button for relative mode. It subtracts a stored value from the present
value. Displays shows Δ.
Resistance measurement
(See fig 1)
1. Insert red test lead into the HzDuty%VΩ terminal and black test lead into the
COM terminal.
2. Set the rotary switch to Ω position. Displays shows Ω.
3. Push RELΔ button for manual ranging. AUTO disappere from the display. When
the value is
unknown always start from highest range.
4. Connect the test leads across with the object being measured. The measured
value shows on the display.
Note
• The test leads can add 0.1Ω to 0.3Ω of error to resistance measurement. To
obtain precision readings in low-resistance measurement, that is the range of 200Ω,
short-circuit the input terminals beforehand and record the reading obtained. This is
the additional resistance from the test lead.
• OL displays when the circuit is open or the resistor value is higher than max
range.