Descargar Imprimir esta página

Federal Signal VAMA LE-106CH Manual Del Usuario página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

LE-106CH / LE 106DCH LAMP REPLACEMENT
1- Remove the lens making it rotate anti-clockwise. (Fig.1)
2- Remove the Fresnel lens by pulling it out. (Fig.2).
3- View of the strobe lamp. (Fig.3).
4- Removal of the strobe lamp. Press the flukes of the lamp assembly and take it out with the help
of a screwdriver. (Fig.4).
Fig. 1
Fig. 3
ELECTRICAL CONNECTION LE-106CH
Use a 1.5 mm cable for both the positive and the negative. Connect the positive to the
positive battery terminal or a good positive
connection near to it.
In 12 Volt installations protect the installation
with a 7.5 A fuse (5 A for 24V). The fuse must be
placed as near as possible to the positive
connection. The electronic circuit must also be
protected by a fuse placed in the interior of the
light.
The reverse of the polarity will cause the
blown of the fuse which will have to be replaced.
Fig. 2
Fig. 4
LE-106CH
18
DO NOT REVERSE
THE POLARITY
NOT SUPPLIED
7,5A (12V)
5A (24V)
red
+ BAT. (12 O 24V)
brown
- BAT. (12 O 24V)