Caution!
Apply the pliers to the area with the largest diameter (a) behind the small sprocket
wheel.
If the sprocket wheel is damaged, the temperature selector cannot be installed.
23.5 Use pliers to remove the thermal element (c).
☞
Important!
Note the installation position of the thermal element.
23.6 Reassemble in reverse order.
23.7 Set the scald protection (see
24. Replacing the flow rate regulator
24.1 Release the grub screw with an Allen key.
24.2 Pull the shower head out of the connection pipe.
24.3 Remove the locking ring on the inside using appropriate pliers for locking rings.
24.4 Pull out the flow rate regulator using flat-nosed pliers.
24.5 Replace the flow rate regulator. Observe the table.
Flow rate
0.15 l/s (orange)
0.20 l/s (red)
☞
Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
24.6 Insert the flow rate regulator and secure with the locking ring.
a: Struts
b: Direction of flow
24.7 Reassemble in reverse order.
Chapter
16.).
Flow rate regulator
FAR-Best.-Nr. 2000104782
FAR-Best.-Nr. 2000104783
- 13 -