Replacing The Non-Return Valve - Franke AT3O0039 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

25. Replacing the non-return valve

Warning!
All non-return valves must be replaced at the same time.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
25.1 Remove the shower panel (see
25.2 Loosen the cap nuts (b).
25.3 Remove the hoses (a).
25.4 Remove the existing seals (c).
25.5 Remove the locking ring (d) on the inside using appropriate pliers for locking rings.
25.6 Pull the non-return valve (e) out of the function block using a special tool
(FAR-Best.-Nr. 2000105636).
25.7 Remove the lock (f) using an Allen key.
25.8 Remove the spacer (g).
25.9 Pull the non-return valve (h) out of the function block (i) using a special tool
(FAR-Best.-Nr. 2000105636).
Caution!
Note the installation position of the non-return valves.
25.10 Reassemble in reverse order.
Chapter
19.).
- 14 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

At3o004176129822177227612982217883

Tabla de contenido