3. Hardware Requirements and Precautions

1.
Whether under RAID 0 or RAID 1 mode, both hard drives of MR2 must be installed into the
system for the device to work properly.
2.
Only one interface connection of MR2
3.
For the best performance and stability of the system, it's strongly recommended that you install
two hard drives of the same capacity, model and manufacturer as top priority. And if necessary,
please also replace faulty hard drives with those of the same model, capacity and manufacturer.
If the same model of HDD is unavailable, please replace it with a model of 20GB or larger in
capacity.
4.
Under RAID 1 and RAID 0 mode, please do not install hard drives containing important data to
MR2 series. Data in hard drives would be erased in system initialization. New hard drives are
recommended to be installed.
5.
The available storage capacity of MR2 identified by the computer may differ from the stated
storage capacity once the drives in the system have been installed and formatted.
6.
To turn off or remove MR2, always safely dismount the volume from the operating system before
removing MR2 from host computer.
7.
Do not remove the hard drive(s) while the system is powered on. Always remember to power off
the unit prior to removing the hard drives.
8.
Under RAID 1 mode, only 1 hard disk failure is permitted.
drives failed under RAID 1 mode, or single hard disk failure under RAID 0 mode, data you
previously stored might have been corrupted or lost.
services.
9.
It is highly recommended that users back up important data to a storage device other than MR2
itself, and/or a remote backup site. STARDOM will not be responsible for any corruption or loss
of data.
10.
The default setting of MR2 is RAID 1 mode. Users are suggested to set it according to your
usage. For data protection, please set it to RAID 1 mode. For storage capacity needs, please
set it to RAID 0 mode. Data in hard drives would be corrupted due to the resetting after use.

4. Hardware Installation

Please follow the instructions below to complete the hardware installation.
Step 1 Place the system on a stable surface. Ensure that the vent is not blocked and that
installed in a well-ventilated
environment that might be harmful to the product)
Step 2 Use the provided key in the accessory kit to eject the removable tray, and then pull tray
handle to remove it.
All manuals and user guides at all-guides.com
may be used at a time per computer system.
area. (Please keep the product away from moisture and other
4
STARDOM MR2 User Manual
Therefore, when you find two hard
Please seek for help from
!"#"$%&'()$*
!"#"$%&'()$*
data recovery
it is

Publicidad

Tabla de contenido
loading

Tabla de contenido