Operating Instructions
GB
Max. working area
Air flow step 1
Air flow step 2
Dehumidifying at 20˚C and 70% r.h.
Dehumidifying at 30˚C and 80% r.h.
Power at 20˚C and 70% r.h.
Power consumption at 20˚C and 70% r.h.
Tank volume
Refrigerant
Charge
Voltage
Frequency
Current
IP Code
Dimensions in mm, L x Bx H
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as
temperature, ventilation and humidity.
PROBLEM
Dehumidifier does not start
Does not dehumidify
High noise level
Ice formation on cooling coils
No water enters reservoir
Does not turn off when water
reservoir is full
The Led is flashing in green
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as
temperature, ventilation and humidity.
8
TECHNICAL DATA
WCD2 Pro
WCD3 Pro
140m
2
190 m
2
190m
/h
197m
/h
3
3
336m
3
/hour
336m
3
/hour
11 l/24h
12l/24h
19 l/24h
25,5l/24h
320 W
420 W
7,3 kWh/24h
9,3kWh/24
11,4 litres
11,4 litres
R290
R290
110 g
120 g
230V
230V
50Hz
50Hz
2,2 A
3 A
IPX1
IPX1
508x464x595
508x464x595
SOLUTION
-
Check that dehumidifier is connected to electricity and that fuse has not gone
-
If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
-
Check that hygrostat is working. Dehumidifier should start when hygrostat is in Maximum position
-
Check that fan is spinning
-
Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
-
Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops. Wait initially for about 35
minutes.
-
Check that a thick coating of ice has not formed on the cooling coils.
-
Increase distance between dehumidifier and surrounding surfaces
-
Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils
-
Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing passage of air through machine
-
Check for obstruction to drip-tray above water reservoir
-
It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping
- To low temperature- increase room temperature.
WCD4 Pro
230 m²
129m
/h
3
296m
3
/hour
25l/24h
41l/24h
500 W
12kWh/24
11,4 litres
R290
150 g
230V
50Hz
3,3 A
IPX1
508x464x595