Technical Data - WOOD'S MDK11 Manual De Instrucciones

Ocultar thumbs Ver también para MDK11:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Operating Instructions
GB
Max. working area
Air flow
Dehumidifying at 30˚C and 80% r.h.
Power at 30˚C and 80% r.h.
Tank volume
Refrigerant
Voltage
Frequency
Current
IP Codet
Dimensions in mm, LxWxH
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as
temperature, ventilation and humidity.
PROBLEM
Dehumidifier does not work
Does not dehumidify
The dehumidifier works, but
reduces the relative huidity
insufficiently.
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
6

TECHNICAL DATA

MDK11
50m
2
77m3/h
10 L/ 24h
210 W
1,8 liters
R290 (55g)
230V
50Hz
0,95A
IP22
290x190x478
CAUSE
SOLUTION
The power is not connected
-
Check that dehumidifier is connected to electricity and that fuse has not gone
-
Check that the water reservoir is empty and correctly placed in the dehumidifier.
-The water container is full.
-
Remove the water from the container.
-The water container has not
-
Place the water container in the correct position.
been replaced correctly.
-The air filter is clogged.
-
Clean the air filter.
The temperature or relative
humidity in the room where
the device is operatingis too low.
-
Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
-
Check that a thick coating of ice has not formed on the cooling coils.
-The room is too large.
-
We recommend using a dehumidifier with a greater capacity.
-There are too many sources
-
We recommende using a dehumidifier with a greater capacity.
of humidity.
-There is too much ventilation.
-
Reduce ventilation (e.g close windows and shut doors.)