INFOSEC UPS SYSTEM XP Pro evolution 1000 VA Guia Del Usuario página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
All manuals and user guides at all-guides.com
7 . I N S T A L L A T I O N A N D O P E R A T I O N
1. Checking
When you receive your equipment, open the packaging and check that your UPS has not
been damaged. The packaging includes: a UPS unit, 1 input power cord, 3 IEC output
cables, 1 communication interface cable (USB connector), 1 RJ11 cable, 1UPSurf Control
Software and a user guide. In the event of damage, please submit a standard claim to the
after-sales department.
2. Charging the batteries
This unit is shipped from the factory with its internal battery fully charged, however, some
charge may be lost during shipping and the battery should be recharged prior to use. Plug
the unit into an appropriate power supply and allow the UPS to charge fully by leaving it
plugged-in, with no load, for at least 8 hours.
The UPS will automatically recharge its own batteries whenever the switch is in the "ON"
position ("ON LINE" green led on). You may use the UPS immediately however the back-up
power capacity may be lower than the nominal value required.
3. Where to set up
The UPS has been designed to operate in a protected environment, at temperatures
between 0° C and 40° C and at a humidity level ranging between 0 % and 90% (no
condensation).
Do not obstruct the ventilation slots. Install the unit in an environment which is free from
dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep
the UPS at least 20 cm away from the CPU (central processing unit).
4. Connection
Check on the identification plate at the back of the UPS that the power supply is compatible
with network voltage and that the device is powerful enough to protect the given power load.
Plug the UPS into a 2-pole, earthed outlet (use the original power cable of your computer or
a 2P+E/CEE22/10A power cable is recommended). Then, use the 3 IEC cables to connect
one computer-related device to each of the power outlets supplied on the back of the UPS.
5. On/Off
To turn the UPS unit on, lightly press the power switch. To turn it off, press the power switch
again. Make sure that the power switch is kept in "on" position, otherwise the UPS will be
disabled and your equipment not protected in case of power failure.
Note: For maintenance purpose, please turn the UPS on before the PC and other loads, and
turn it off after the connected loads are turned off.
6. DC Start
XP Pro evolution units are equipped with a built-in DC start function. To start the UPS in the
absence of a power supply and with a fully-charged battery, press the button.
7. Power Saving Function
XP Pro evolution comes with a Power Saving Function. If no load connects to the UPS, it will
automatically shut down after 5 minutes to save energy during a power failure. The Power
switch must be kept in the 'ON' position, otherwise, the UPS will be disabled and your
equipment will not be protected during a power failure.
6
INFOSEC UPS SYSTEM - 4, rue de la Rigotière – 44700 Orvault – FRANCE - www.infosec-ups.com
Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 10 06 04 206 10

Publicidad

Tabla de contenido
loading

Tabla de contenido