Ground pump and motor in accordance with
the local codes and ordinances. Use a copper
ground wire at least as large as wires carrying
current to motor.
Motor is supplied with a copper ground wire.
Splice this ground wire to a copper conductor that
matches motor wire size specified in Table III. See
Page 5 for wire splicing instructions.
Permanently ground pump, motor and control box
before connecting power cable to power supply.
Connect ground wire to approved ground first and
then connect to equipment being installed.
do not ground to a gas supply line.
Fire and electrical shock hazard. If
using a drop wire larger than No. 10 (5.5mm
example, No. 8 (8.4mm
) wire) between pump and
2
control box, run wire to a separate junction box.
Connect junction box to control box with a No.
10 (5.5mm
) or smaller wire (depending on amp
2
rating of pump – see Table III).
For more information, contact your local code
officials.
WIRING CONNECTIONS:
All wiring must meet National Electrical Code or
Canadian Electrical Code and local code require-
ments. Use only copper wire when making connec-
tions to pump and control box.
To avoid over-heating wire and excessive voltage
drop at motor, be sure that wire size is at least as
large as size listed in Table III for your horsepower
pump and length of wire run.
NOTICE When built-in overheating protection
is not provided, use with an approved overload
equipped motor control that matches motor input in
full load amps. Select or adjust overload element(s)
in accordance with control instructions. When
built-in overheating protection is provided, use
with an approved motor control that matches motor
input in full load amperes.
TABLE III: Copper
Cable Length in Feet (Service to Motor)
Motors: 1 Ph, 3-Wire Cable, 60 Hz. Wire Size
2
HP
Volts
14
W
1/2
115
110
I
1/2
230
438
R
3/4
230
365
1
230
304
E
1-1/2
230
219
Motors: 1 Ph, 3-Wire Cable, 60 Hz. Wire Size
3
HP
Volts
14
W
1/2
115
82
I
1/2
230
348
R
3/4
230
267
1
230
203
E
1-1/2
230
160
All cable lengths meet NEC for jacketed 60°C copper cable. Based on 3-Wire Induction Run requirements; Capacitor Run requirements may vary. Local
code requirements may vary. For aluminum cable, go up two sizes from chart (for example, if the chart calls for No. 10 AWG (6mm
No. 8 AWG (10mm
2
) for aluminum; the smaller the number, the larger the cable). Use oxidation inhibitors on the connections.
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
All manuals and user guides at all-guides.com
TABLE I:
Single Phase, 3 Wire Submersible Pump Motors
TABLE II:
Single Phase 2 Wire Submersible Pump Motors
) (for
2
INSTALLATION WIRING dIAGRAMS -
SINGLE PHASE, 3 WIRE
magnetic starter to avoid damage to pressure switch.
Consult factory for wiring information.
See Page 4 for 2 Wire Hookup.
or kill.
Ground control box, all metal plumbing, and motor
frame with copper wire in compliance with local
codes. Use a ground wire at least as large as the
wires supplying power to motor.
Permanently close all unused openings in this and
other equipment.
Disconnect power to control box before working
on or around control box, pipes, cable, pump, or
motor.
Wire Size, AWG
12
10
8
6
174
278
440
685
697
1112
1761
2740
581
927
1468
2284
484
772
1223
1903
349
556
881
1370
Wire Size, AWG
12
10
8
6
130
207
329
511
553
883
1398
2175
425
678
1074
1671
323
515
815
1269
254
406
643
1000
3
Recommended Fusing data - 60 Hz.,
Fuse Size
HP
Volts
Stand
Dual Elem.
1/2
115
40
1/2
230
15
3/4
230
25
1
230
30
1-1/2
230
40
Recommended Fusing data - 60 Hz.,
Fuse Size
HP
Volts
Stand
Dual Elem.
1/2
115
30
1/2
230
15
3/4
230
15
1
230
20
1-1/2
230
20
For motors of 1
Hazardous voltage. Can shock, burn,
4
3
2
1
1092
1373
1734
2184
4369
5492
6936
8738
3641
4577
5780
7281
3034
3814
4817
6068
2184
2746
3468
4369
4
3
2
1
815
1025
1294
1630
3467
4359
5505
6935
2664
3349
4229
5328
2023
2543
3211
4045
1594
2004
2531
3189
C.B.
25
35
10
15
15
20
15
25
20
30
C.B.
15
25
10
10
10
15
15
20
20
25
⁄
HP and above, use
1
2
0
00
2757
3479
11029
-
9191
11596
7659
9663
5515
6957
0
00
2058
2596
8753
-
6725
8485
5106
6442
4025
5078
2