CH 3 Gobo Rotation
Value#
0
1-99
100-155
156-255
In DMX mode and SLAVE mode, the lamp will be blacked out automatically if there is no DMX signal
input.
SERVICE:
There are no user serviceable parts inside except the lamp. Refer all service to a qualified technician.
Lamp replacement:
1. Disconnect the fixture from AC power and allow it to cool for 15 minutes.
2. Loosen the access screws and lift the cover.
3. Remove the base of the old lamp from the socket.
4. Install the new lamp: ELC 24 V/250 W GX5.3 halogen.
Push the lamp base pins fully, but gently, into the socket.
To ensure maximum lamp life, avoid touching the lamp with bare hands.
Replace the main fuse:
1. Unplug the mains cable from the output socket.
2. Open the fuse holder and replace the fuse with one of the same type. The fuse rating is listed on
the rating label.
TROUBLESHOOTING:
Problem
One or more fixtures are
completely dead.
Fixture is working correctly but
no light output.
Fixtures reset correctly but
all respond erratically or not
at all to controller.
Fixtures reset correctly but
some respond erratically or
not at all to controller.
All manuals and user guides at all-guides.com
Function
STOP
CW
STOP
CCW
Probable cause
No power to the fixture.
Main fuse blown.
Broken or worn out lamp.
Controller not connected.
XLR pin-out of controller does
not match pin-out of first fixture
on link (polarity is reversed).
Bad data link connection.
Data link not terminated with
120 Ohm termination plug.
Incorrect fixture addressing.
One of the fixtures is
transmitting as a master.
5
Solution
Make sure that cables are
plugged in and power is switched
on.
Replace fuse.
Install new lamp.
Connect controller.
Install a phase-reversing cable
between controller and first
fixture on link.
Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables.
Insert termination plug in output
of last fixture on link.
Check DMX addresses.
Check all fixture settings.