the public electricity company. Such leakage could electrocute the workers of the public electricity company
working on the network or other persons in contact with the line during a power cut. Also, when the public
power supply is re-established, the generator can explode, catch fire or generate fires in the building's
electrical installation.
Before connecting electrical devices to the generator, make sure that their voltage specifications and
frequency of functioning correspond to the technical characteristics of the generator. There may be
damage if the device connected is not designed to function with a voltage tolerance of +/- 10% or a
frequency tolerance of +/- 3 % compared with those of the generator.
Protection of the environment
You must periodically check the silencer (Before doing this, switch off the generator and let it cool
completely). A damaged silencer increases noise.
Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose.
The fuel for this machine is combustible and explosive. After stopping the machine, you must handle the
remaining fuel correctly and meet local environmental requirements.
To dispose of residual fluids, proceed as follows:
Close the fuel tap
Drain fuel from the fuel tank
Empty carburettor fuel
Symbol explanation
Attention!
Please read the manual carefully before using the unit!
Conforms to relevant safety standards
Do not dispose of old appliances with domestic rubbish .
Add engine oil.
Guaranteed sound power level
No naked flames
Ground connection
It is forbidden to run the generator in an enclosed room because exhaust emissions can lead
humans or animals to coma to death.
This symbol indicates the surface is very hot and not touching
Keep away from the machine