Electrical Requirements - Maytag PAV2300AGW Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Dryer Dimensions
43 ³⁄₈"
(110 cm)
*27 ³⁄₄"
(70.5 cm)
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the
exhaust vent with elbow. See "Venting Requirements."
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested
for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be
considered for the following reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings.
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom
of the door are required. Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
18"*
(45.7 cm)
29"
1"
1"
(2.5 cm)
(2.5 cm)
(73.66 cm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
All manuals and user guides at all-guides.com
22 ³⁄₄"
(57.8 cm)
29"
(73.66 cm)
(7.6 cm)
14" max.*
48 in.
2
*
(35.6 cm)
2
(310 cm )
2
*
24 in.
2
(155 cm )
(7.6 cm)
27¾"
5"*
1"*
(70.5 cm)
(12.7 cm)
(2.5 cm)
B
C
It is your responsibility
To contact a qualified electrical installer to assure that the electrical installatio is adequate
and is in conformance with all local codes and ordinances.
To supply the required 2 wire, single phase, 230 volt, 50 Hz., AC only electrical supply
on a separate 30-amp circuit. A time-delay fuse or circuit breaker is recommended.
Connect to an individual branch circuit.
Electrical ground is required on this dryer.
Do not ground to a gas pipe.
Do not change the power supply cord plug. If it does
not fit the outlet, have a proper outlet installed by a
qualified electrician.
Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord with this dryer.
Check with a qualified electrician to be sure the dryer is
properly grounded.
Do not connect plug end of power supply cord into a
live receptacle before connecting power supply cord to
dryer terminal block.
3"*
Do not reuse old power supply cord.
Failure to follow these instructions could result in
death, fire, or serious injury.
To minimize possible shock hazard, the cord must be plugged into a mating receptacle.
Be sure wall receptacle is within reach of dryer's final location.
3"*
For information on ordering parts, see the Assistance or Service section.

Electrical Requirements

WARNING
Electrical Shock Hazard
7

Publicidad

Tabla de contenido
loading

Tabla de contenido